{"title":"Current \u0026 Voltage","description":"","products":[{"product_id":"spannungs-und-stromsensor-jeti-mui-30-bis-30a-fur-jeti-duplex-2-4ghz-system","title":"Voltage and Current Sensor Jeti MUI 30 (up to 30A) for Jeti Duplex 2.4Ghz System","description":"\u003ch1 style=\"text-align: center;\"\u003eVoltage and Current Sensor Jeti MUI30 (up to 30A) for Jeti Duplex 2.4Ghz System\u003c\/h1\u003e\n\n\u003cp\u003eThe \u003cb\u003eMUI sensors\u003c\/b\u003e are designed to measure voltage, current, and consumed battery capacity in the model. The JETIBOX terminal is used to display the measured values, and the DUPLEX 2.4GHz system is used for wireless transmission of the information. \u003cbr\u003e\nThe DUPLEX system uses the 2.4GHz band for communication, which not only allows the transmission of remote control data to the model but also the transmission from the model back to the transmitter. The telemetry data acquired during operation is transmitted in real-time, and the current status of the measured values can be displayed on the LCD screen of the JETIBOX. The MUI telemetry sensors allow you to measure voltages and currents in your model and transmit this information using the DUPLEX system (receiver and transmitter module). Thanks to the high current measurement accuracy, these sensors allow you to monitor the consumed capacity of the measured battery. In addition to the duration of current flow, the MUI unit also records the average and maximum values of the current. Furthermore, it provides precise voltage values as well as their minimum and maximum values.\u003cbr\u003e\nThe JETIBOX terminal is used to set parameters and display the measured values.\u003cbr\u003e\nThe MUI sensors allow setting an audible signal when exceeding specified parameters. This alarm can be set for measuring maximum current, minimum voltage, and maximum permissible capacity consumption. The audible signal is generated by the transmitter module via a built-in sound generator. Individual alarm messages are distinguished by assigning a Morse code letter. The audible signals for parameter overruns are generated even if no JETIBOX is connected. When a JETIBOX is connected, the LCD display indicates which parameter has been exceeded. In the event of multiple parameters being exceeded, the audible signals and LCD display indications alternate.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eManufacturer: Jeti Model\u003c\/li\u003e\n\t\u003cli\u003eOperating voltage: 5 - 8.4 V\u003c\/li\u003e\n\t\u003cli\u003eCurrent consumption approx.: 24 mA \u003c\/li\u003e\n\t\u003cli\u003eDimensions approx.: 20x16.5x5 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight approx.: 10 grams\u003c\/li\u003e\n\t\u003cli\u003eVoltage measurement range: 0 - 60 V\u003c\/li\u003e\n\t\u003cli\u003eCurrent measurement range: 0 - 30 A\u003c\/li\u003e\n\t\u003cli\u003eAccuracy: Current\/Voltage 1% \/ 0.1%\u003c\/li\u003e\n\t\u003cli\u003eOperating temperature: -10°C - 85°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JETI model, s. R. O.","offers":[{"title":"Default Title","offer_id":53441106116951,"sku":"H80001302","price":36.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/H80001302_b1.jpg?v=1782297821"},{"product_id":"spannungs-und-stromsensor-jeti-mui-75-ex-bis-75a-fur-jeti-duplex-2-4ghz","title":"Voltage and Current Sensor Jeti MUI 75 EX (up to 75A) for Jeti Duplex 2.4Ghz","description":"\u003ch1 style=\"text-align: center;\"\u003eVoltage and Current Sensor Jeti MUI75 (up to 75A) for Jeti Duplex 2.4Ghz System\u003c\/h1\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe \u003cb\u003eMUI sensors\u003c\/b\u003e are designed to measure voltages, currents, and consumed battery capacity in the model. The JETIBOX terminal is used to display the measured values, and the DUPLEX 2.4GHz system is used for wireless data transmission. \u003cbr\u003e\nThe DUPLEX system uses the 2.4GHz band for communication, which not only allows the transmission of remote control data to the model, but also the transmission from the model back to the transmitter. The telemetry data acquired during operation is transmitted in real-time, and the current status of the measured quantities can be displayed on the JETIBOX LCD screen. The MUI telemetry sensors allow the measurement of voltages and currents in your model and transmit this information using the DUPLEX system (receiver and transmitter module). Thanks to the high current measurement accuracy, these sensors allow you to track the consumed capacity of the measured battery. In addition to the duration of current flow, the MUI unit also records the average and maximum current values. Furthermore, it provides precise voltage values as well as their minimum and maximum values.\u003cbr\u003e\nThe JETIBOX terminal is used to set parameters and display the measured values.\u003cbr\u003e\nThe MUI sensors allow the setting of an audible signal when set parameters are exceeded. This alarm can be set for measuring maximum current, minimum voltage, and maximum permissible capacity consumption. The audible signal is generated by the transmitter module via a built-in sounder. Individual alarm messages are distinguished from each other by assigning a Morse code letter. Audible signals for parameter overruns are also generated even if no JETIBOX is connected. If a JETIBOX is connected, the LCD display indicates which parameter has been exceeded. In the event of multiple parameters being exceeded, the acoustic signals and LCD display indications alternate.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical Data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eManufacturer: Jeti Model\u003c\/li\u003e\n\t\u003cli\u003eOperating voltage: 5 - 8.4 V\u003c\/li\u003e\n\t\u003cli\u003eCurrent consumption approx.: 32 mA\u003c\/li\u003e\n\t\u003cli\u003eDimensions approx.: 27x19x11 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight approx.: 15 grams\u003c\/li\u003e\n\t\u003cli\u003eVoltage measurement range: 0 - 60 V\u003c\/li\u003e\n\t\u003cli\u003eCurrent measurement range: 0 - 75 A\u003c\/li\u003e\n\t\u003cli\u003eAccuracy: Current\/Voltage 1% \/ 0.1%\u003c\/li\u003e\n\t\u003cli\u003eOperating temperature: -10°C - 85°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JETI model, s. R. O.","offers":[{"title":"Default Title","offer_id":53441106411863,"sku":"H80001303","price":40.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/H80001303_b1.jpg?v=1782297831"},{"product_id":"spannungs-und-stromsensor-jeti-mui-150-bis-150a-fur-jeti-duplex-2-4ghz-system","title":"Voltage and Current Sensor Jeti MUI 150 (up to 150A) for Jeti Duplex 2.4Ghz System","description":"\u003ch1 style=\"text-align: center;\"\u003eVoltage and Current Sensor Jeti MUI150 (up to 150A) for Jeti Duplex 2.4Ghz System\u003c\/h1\u003e\n\n\u003cp\u003eThe \u003cb\u003eMUI sensors\u003c\/b\u003e are designed to measure voltage, current, and consumed battery capacity in the model. The JETIBOX terminal is used to display the measured values, and the DUPLEX 2.4GHz system is used for wireless transmission of information. \u003cbr\u003e\nThe DUPLEX system uses the 2.4GHz band for communication, which not only allows the transmission of remote control data to the model but also the transmission from the model back to the transmitter. The telemetric data obtained during operation is transmitted in real-time, and the current status of the measured values can be displayed on the JETIBOX's LCD screen. The MUI telemetric sensors enable the measurement of voltages and currents in your model and transmit this information using the DUPLEX system (receiver and transmitter module). Thanks to the high current measurement accuracy, these sensors allow you to track the consumed capacity of the measured battery. In addition to the duration of current flow, the MUI unit also records the average and maximum current values. Furthermore, it provides precise voltage values as well as their minimum and maximum values.\u003cbr\u003e\nThe JETIBOX terminal is used to set parameters and display measured values.\u003cbr\u003e\nThe MUI sensors allow setting an audible signal when set parameters are exceeded. This alarm message can be set for measuring maximum current, minimum voltage, and maximum permissible capacity consumption. The audible signal is generated by the transmitter module via a built-in sounder. Individual alarm messages are distinguished by assigning a Morse code letter. The audible signals for parameter overruns are also generated even if no JETIBOX is connected. If a JETIBOX is connected, the LCD display shows which parameter has been exceeded. If multiple parameters are exceeded, the audible signals and LCD display indications alternate.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical Data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eManufacturer: Jeti Model\u003c\/li\u003e\n\t\u003cli\u003eOperating voltage: 5 - 8.4 V\u003c\/li\u003e\n\t\u003cli\u003eCurrent consumption approx.: 24 mA\u003c\/li\u003e\n\t\u003cli\u003eDimensions approx.: 29x19x11 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight approx.: 21 grams\u003c\/li\u003e\n\t\u003cli\u003eVoltage measurement range: 0 - 60 V\u003c\/li\u003e\n\t\u003cli\u003eCurrent measurement range: 0 - 150 A\u003c\/li\u003e\n\t\u003cli\u003eAccuracy: Current\/Voltage 1% \/ 0.1%\u003c\/li\u003e\n\t\u003cli\u003eOperating temperature: -10°C - 85°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JETI model, s. R. O.","offers":[{"title":"Default Title","offer_id":53441107329367,"sku":"H80001304","price":50.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/H80001304_b1_f6e7ffe2-04ba-4edb-bced-898a43654226.jpg?v=1782297840"},{"product_id":"spannungs-und-stromsensor-jeti-mui-50-bis-50a-fur-jeti-duplex-2-4ghz-system","title":"Voltage and Current Sensor Jeti MUI 50 (up to 50A) for Jeti Duplex 2.4Ghz System","description":"\u003ch1 style=\"text-align: center;\"\u003eVoltage and Current Sensor Jeti MUI 50 (up to 50A) for Jeti Duplex 2.4Ghz System\u003c\/h1\u003e\n\n\u003cp\u003eThe \u003cb\u003eMUI sensors\u003c\/b\u003e are designed to measure voltages, currents, and consumed battery capacity in the model. The JETIBOX terminal is used to display the measured values, and the DUPLEX 2.4GHz system is used for wireless transmission of the information. \u003cbr\u003e\nThe DUPLEX system uses the 2.4GHz band for communication, which not only allows the transmission of remote control data to the model but also the transmission from the model back to the transmitter. The telemetry data acquired during operation is transmitted in real-time, and the current status of the measured values can be displayed on the LCD screen of the JETIBOX. The MUI telemetry sensors allow the measurement of voltages and currents in your model and transmit this information with the help of the DUPLEX system (receiver and transmitter module). Thanks to the high current measurement accuracy, these sensors allow you to track the consumed capacity of the measured battery. In addition to the duration of current flow, the MUI unit also records the average and maximum current values. Furthermore, it provides precise voltage values as well as their minimum and maximum values.\u003cbr\u003e\nThe JETIBOX terminal is used for setting parameters and displaying the measured values.\u003cbr\u003e\nMUI sensors allow the setting of an acoustic signal when set parameters are exceeded. This alarm message can be set for measuring maximum current, minimum voltage, and maximum permissible capacity consumption. The acoustic signal is generated by the transmitter module via a built-in sounder. Individual alarm messages are distinguished by assigning a Morse code letter. Acoustic signals for parameter exceedances are also generated even if no JETIBOX is connected. If a JETIBOX is connected, the LCD display shows which parameter has been exceeded. In the event of multiple parameters being exceeded, the acoustic signals and LCD display indications alternate.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eManufacturer: Jeti Model\u003c\/li\u003e\n\t\u003cli\u003eOperating voltage: 5 - 8.4 V\u003c\/li\u003e\n\t\u003cli\u003eCurrent consumption approx.: 32 mA\u003c\/li\u003e\n\t\u003cli\u003eDimensions approx.: 27x19x11 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight approx.: 15 grams\u003c\/li\u003e\n\t\u003cli\u003eVoltage measuring range: 0 - 60 V\u003c\/li\u003e\n\t\u003cli\u003eCurrent measuring range: 0 - 50 A\u003c\/li\u003e\n\t\u003cli\u003eCurrent\/voltage accuracy: 1% \/ 0.1%\u003c\/li\u003e\n\t\u003cli\u003eOperating temperature: -10°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JETI model, s. R. O.","offers":[{"title":"Default Title","offer_id":53441107427671,"sku":"H80001307","price":37.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/H80001307_b1_c91a4e4c-9324-4a37-a2bb-b8348bb084a0.jpg?v=1781274515"},{"product_id":"spannungs-und-stromsensor-jeti-mui-200-bis-200a-fur-jeti-duplex-2-4ex-system","title":"Voltage and Current Sensor Jeti MUI 200 (up to 200A) for Jeti Duplex 2.4EX System","description":"\u003ch1 style=\"text-align: center;\"\u003eVoltage and Current Sensor Jeti MUI200 (up to 200A) for Jeti Duplex 2.4EX System\u003c\/h1\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe \u003cb\u003eMUI sensors\u003c\/b\u003e are designed for measuring voltage, current, and consumed battery capacity in the model. The JETIBOX terminal is used to display the measured values, and the DUPLEX 2.4GHz system is used for wireless transmission of information. \u003cbr\u003e\nThe DUPLEX system uses the 2.4GHz band for communication, which not only allows the transmission of remote control data to the model but also the transmission from the model back to the transmitter. The telemetry data obtained during operation is transmitted in real-time, and the current status of the measured values can be displayed on the LCD screen of the JETIBOX. The MUI telemetry sensors enable the measurement of voltages and currents in your model and transmit this information using the DUPLEX system (receiver and transmitter module). Thanks to their high current measurement accuracy, these sensors allow you to track the consumed capacity of the measured battery. In addition to the duration of current flow, the MUI unit also records the average and maximum current values. Furthermore, it provides accurate voltage values as well as their minimum and maximum values.\u003cbr\u003e\nThe JETIBOX terminal is used for setting parameters and displaying the measured values.\u003cbr\u003e\nThe MUI sensors allow setting an audible signal when set parameters are exceeded. This alarm message can be set for measuring the maximum current, minimum voltage, and the maximum permissible capacity consumption. The audible signal is generated by the transmitter module via a built-in sounder. Individual alarm messages are distinguished by assigning a Morse code letter. Audible signals for parameter overruns are also generated even when no JETIBOX is connected. If a JETIBOX is connected, the LCD display shows which parameter has been exceeded. In the event of multiple parameters being exceeded, the acoustic signals and LCD display indications alternate.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eManufacturer: Jeti Model\u003c\/li\u003e\n\t\u003cli\u003eOperating voltage: 5 - 8.4 V\u003c\/li\u003e\n\t\u003cli\u003eCurrent consumption approx.: 32 mA\u003c\/li\u003e\n\t\u003cli\u003eDimensions approx.: 29x19x11 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight approx.: 26 grams\u003c\/li\u003e\n\t\u003cli\u003eVoltage measuring range: 0 - 60 V\u003c\/li\u003e\n\t\u003cli\u003eCurrent measuring range: 0 - 200 A\u003c\/li\u003e\n\t\u003cli\u003eAccuracy current\/voltage: 1% \/ 0.1%\u003c\/li\u003e\n\t\u003cli\u003eOperating temperature: -10°C - 85°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JETI model, s. R. O.","offers":[{"title":"Default Title","offer_id":53441109492055,"sku":"H80001313","price":57.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/H80001313_b1_b9476e4d-5156-4242-9bfc-48500bd07255.jpg?v=1782297858"},{"product_id":"hepf-voltario-s30-telemetrie-zur-stromuberwachung-eines-servos-mvs30","title":"HEPF Voltario S30 Telemetry for Servo Current Monitoring, # MVS30","description":"\u003ch1 style=\"text-align: center;\"\u003eHEPF Voltario S30 Telemetry\u003cbr\u003e\nfor Servo Current Monitoring, # MVS30\u003c\/h1\u003e\n\n\u003cp\u003eThe Voltario S30 is used to monitor the current consumption of a single servo. It offers an additional option to set an overcurrent protection shutdown.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eDuplex Telemetry (current, voltage, capacity)\u003c\/li\u003e\n\t\u003cli\u003eHOTT Telemetry (current, voltage, capacity)\u003c\/li\u003e\n\t\u003cli\u003eFutaba Telemetry (1678 Port3 - current, voltage, capacity) \u003c\/li\u003e\n\t\u003cli\u003eJetiBox compatible\u003c\/li\u003e\n\t\u003cli\u003eOptional overcurrent shutdown with regeneration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eVoltario S30 Installation:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003ePlug the Voltario S30 between the receiver output channel and the servo. The Voltario S30 works completely autonomously as a programmable fuse (this function must be configured first).\u003c\/p\u003e\n\n\u003cp\u003eTo display the telemetry data, you can connect the Voltario S30 to the receiver (telemetry input) via a JR cable.\u003cbr\u003e\nIf you want to configure the device with a JETIBOX, you must supply the JETIBOX with external voltage, as the red cable is not internally connected in the Voltario S30.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical Data Voltario S30: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eDimensions: 25x12x5mm\u003c\/li\u003e\n\t\u003cli\u003eWeight including cable: 4g\u003c\/li\u003e\n\t\u003cli\u003eContinuous current: max. 10A\u003c\/li\u003e\n\t\u003cli\u003ePeak current: (2s) 30A\u003c\/li\u003e\n\t\u003cli\u003eTemperature range: -20 - 85°\u003c\/li\u003e\n\t\u003cli\u003eOperating voltage: 4-12V\u003c\/li\u003e\n\t\u003cli\u003eTelemetry: Jeti Duplex, Hott, Futaba\u003c\/li\u003e\n\t\u003cli\u003eOvercurrent protection: yes\u003c\/li\u003e\n\t\u003cli\u003eCable: 0.25mm² (23AWG)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HEPF GmbH","offers":[{"title":"Default Title","offer_id":53441625653591,"sku":"HE-MVS30","price":41.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/HE-MVS30_b1.jpg?v=1779798070"},{"product_id":"spektrum-flug-telemetrie-flugakkusensor-2-pin-horizon-spma9570a","title":"Spectrum Flight Telemetry Flight Battery Sensor 2-pin, Horizon # SPMA9570A","description":"","brand":"SPEKTRUM","offers":[{"title":"Default Title","offer_id":53441744011607,"sku":"HHSPMA9570A","price":8.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/HHSPMA9570A_b1.jpg?v=1779977259"},{"product_id":"spannungssensor-fur-m-link-empfanger-multiplex-85400","title":"Voltage sensor for M-LINK receivers, Multiplex # 85400","description":"\u003ch1 style=\"text-align: center;\"\u003e(Similar to illustration) Voltage sensor for M-LINK receivers\u003c\/h1\u003e\n\n\u003cp\u003eVoltage sensor:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eMeasuring range: 0 ... 50 V\u003c\/li\u003e\n\t\u003cli\u003eResolution: 0.1 V\u003c\/li\u003e\n\t\u003cli\u003eDimensions (LxWxH): 30 x 15 x 7 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight: approx. 10 g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Multiplex Modellsp. GmbH\u0026Co.KG","offers":[{"title":"Default Title","offer_id":53445650121047,"sku":"M85400","price":43.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/M85400_b1_bd6d96a6-b63c-4a78-a05f-a64fbc6bfca7.jpg?v=1779805550"},{"product_id":"strom-sensor-35a-fur-m-link-empfangerm-mpx-steckverbindung-multiplex-85403","title":"Current Sensor 35A for M-LINK Receivers (with MPX connector), Multiplex # 85403","description":"\u003ch1 style=\"text-align: center;\"\u003eCurrent Sensor 35A with MPX High-Current Connector M6\u003cbr\u003e\nfor M-LINK receivers, Multiplex # 85403\u003c\/h1\u003e\n\n\u003cp\u003eMeasures currents up to 35 A. \u003cb\u003eEquipped with the M6 plug system\u003c\/b\u003e, the sensor is connected between the battery and the consumer, for example, to measure the current of the electric drive.\u003c\/p\u003e\n\n\u003cp\u003e\"No current, no fun\" - therefore, information about the currents in the model is vital! This is where current sensors come into play. They actually have two functions:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eMeasuring the currently flowing currents, from the drive, receiver, or ECU battery (in jets). Interesting, for example, for optimizing the drive (how much current does my drive draw with which propeller) and for avoiding overload situations. For example, in the basic setting of the model, blocking currents indicate incorrectly adjusted servo throws.\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eDisplaying the remaining charge, essentially the \"fuel gauge\" for the battery. Especially when using modern high-performance LiPo batteries (e.g., Li-BATT FX), the remaining charge display is actually indispensable, as these batteries maintain their voltage almost constant for a very long time during operation, but then \"collapse\" within seconds. This means that voltage-dependent monitoring, e.g., of the receiver battery, is no longer sufficient. Timers can also only be crude aids.\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe sensor is integrated with the pre-assembled MPX high-current plug system between the battery and the consumer. The sensors are connected to telemetry-capable receivers or to another sensor within the MSB. With its basic function \"output of the currently flowing current in A\", the sensor can be put into operation immediately, for example, to measure the current of the electric drive. After activating the charge counter with the MULTImate (# M82094) or the PC program \"MULTIPLEX-Launcher\"**, you will no longer fly by timer in the future, but according to the actual remaining charge of the drive battery. The current sensor thus becomes your electronic fuel gauge! Protect your batteries from excessive discharge and thus prevent a shortened lifespan.\u003c\/p\u003e","brand":"Multiplex Modellsp. GmbH\u0026Co.KG","offers":[{"title":"Default Title","offer_id":53445650186583,"sku":"M85403","price":36.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/M85403_b1_0d482b87-1fba-4a76-af95-d22783e892ed.jpg?v=1779805568"},{"product_id":"strom-sensor-150a-fur-m-link-telemetrie-multiplex-85405","title":"Current Sensor 150A for M-LINK Telemetry, Multiplex # 85405","description":"\u003ch1 style=\"text-align: center;\"\u003eCurrent Sensor 150A for MPX M-LINK Telemetry #85405\u003c\/h1\u003e\n\n\u003cp\u003e\"No current, no action\" - therefore, information about the currents in the model is vital! This is exactly where current sensors come into play.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e These actually have two functions: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003col\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eMeasuring the currently flowing currents, whether from the drive, receiver, or ECU battery (in jets). Interesting, for example, for optimizing the drive (how much current does my drive draw with which propeller) and for avoiding overload situations. For example, during the basic setup of the model, blocking currents indicate incorrectly adjusted servo throws.\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eIndicating the remaining charge, essentially the \"fuel gauge\" for the battery. Especially when using modern high-performance LiPo batteries (e.g., Li-BATT FX), the remaining charge indication is practically indispensable, as these batteries maintain their voltage almost constantly for a very long time during operation, but then \"collapse\" within seconds. This means that voltage-dependent monitoring of, for example, the receiver battery is no longer sufficient. Timers can also only be rough aids.\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003eThe sensor is connected between the battery and the consumer, and connected to telemetry-capable receivers or to another sensor within the MSB. With its basic function \"outputting the currently flowing current\", the sensor can be put into operation immediately, for example, to measure the current of the electric drive. After activating the charge counter with the MULTImate (# M82094) or the PC program \"MULTIPLEX-Launcher\", you will no longer fly by timer, but by the actual remaining charge of the drive battery. The current sensor will thus become your electronic fuel gauge! Protect your batteries from deep discharge and thus prevent a shortened lifespan.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eActivatable\/adjustable with the MULTImate or MULTIPLEX Launcher: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eAlarm low: Lower current value at which an alarm is triggered on the transmitter.\u003c\/li\u003e\n\t\u003cli\u003eAlarm high: Upper current value at which an alarm is triggered on the transmitter.\u003c\/li\u003e\n\t\u003cli\u003eOption 1 Maximum, minimum or average current.\u003c\/li\u003e\n\t\u003cli\u003eMin current\/MiWe: adjustable from 0.0 A to 1.0 A.\u003c\/li\u003e\n\t\u003cli\u003eMinimum current, from which it is counted for the purpose of averaging.\u003c\/li\u003e\n\t\u003cli\u003eWaiting time: Power-on delay (adjustable from 0.0 – 3.0 seconds)\u003c\/li\u003e\n\t\u003cli\u003eDischarged charge or remaining charge. Display in: Charge (mAh) or percent\u003c\/li\u003e\n\t\u003cli\u003eBattery capacity: Capacity of the connected battery.\u003c\/li\u003e\n\t\u003cli\u003eAlarm: Remaining charge value at which an alarm should be triggered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eManufacturer: Multiplex\u003c\/li\u003e\n\t\u003cli\u003eDimensions: approx. 31x25x6.5 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight: approx. 20 grams\u003c\/li\u003e\n\t\u003cli\u003eCurrent measuring range: 0 - 150 A\u003c\/li\u003e\n\t\u003cli\u003eAccuracy: 0.1A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Multiplex Modellsp. GmbH\u0026Co.KG","offers":[{"title":"Default Title","offer_id":53445650252119,"sku":"M85405","price":46.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/M85405_b1_e62f3321-b83d-47f5-ab8e-2aac4c5dbc22.jpg?v=1779805586"},{"product_id":"anschlusskabel-extra-voltage-fur-futaba-telemetrie-empfanger","title":"Connecting Cable Extra Voltage for Futaba Telemetry Receivers","description":"\u003ch1 style=\"text-align: center;\"\u003eConnection Cable Extra Voltage for Futaba Telemetry Receivers\u003c\/h1\u003e\n\n\u003cp\u003eThis cable is suitable for Futaba receivers R3008SB, R6308SBT, R7008SB, R7014SB and R7018SB. It allows external voltages with telemetry to be transmitted to the transmitter.\u003c\/p\u003e","brand":"FUTABA","offers":[{"title":"Default Title","offer_id":53445683839319,"sku":"MC-EBB0141","price":14.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/MC-EBB0141_b1.jpg?v=1779926207"},{"product_id":"futaba-stromsensor-sbs01c-bis-150-ampere-futaba-p-sbs-01c13","title":"FUTABA Current Sensor SBS01C up to 150 Amperes, Futaba # P-SBS\/01C13","description":"\u003ch1 style=\"text-align: center;\"\u003eFUTABA Current Sensor SBS01C up to 150 Amps\u003cbr\u003e\nFutaba # P-SBS\/01C13\u003c\/h1\u003e\n\n\u003cp\u003eWith this Futaba current sensor SBS-01C, currents up to 150A can be measured and transmitted to the transmitter via FASSTest telemetry. The display of consumed capacity and voltage of the used batteries is also possible via telemetry. Ideal for monitoring, for example, the current of the drive motor and the consumed capacity.\u003cbr\u003e\nThe sensor can currently (07\/19) be used with the following transmitters, but please note that older transmitters may require the corresponding software version.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eHandheld transmitters: T4PM, T4PX\/R, T6K V2.0, T7PX, T7XC, T10J, T12K, T14SG, T16SZ, T18SZ, T18MZ, T32MZ\u003c\/li\u003e\n\t\u003cli\u003eTray transmitters: FX-22, FX-32, FX-36\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eCurrent measurement: 0 - 70 A\u003c\/li\u003e\n\t\u003cli\u003eCurrent measurement: 70 - 150 A (max. 10 seconds)\u003c\/li\u003e\n\t\u003cli\u003eVoltage measurement: 0 - 70 V\u003c\/li\u003e\n\t\u003cli\u003eConsumed energy: 0 - 32,700 mAh\u003c\/li\u003e\n\t\u003cli\u003eSupply voltage: 3.7 - 7.4 V\u003c\/li\u003e\n\t\u003cli\u003eWeight 23 g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FUTABA","offers":[{"title":"Default Title","offer_id":53445690229079,"sku":"MC-SBS-01C","price":66.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/MC-SBS-01C_b1_9d154855-4040-4e11-bc03-d6a2eea76fa0.jpg?v=1781253155"},{"product_id":"spannungssensor-sbs01v-fur-futaba-telemetrie-0-100v","title":"Voltage Sensor SBS01V for Futaba Telemetry, 0-100V","description":"\u003ch1 style=\"text-align: center;\"\u003eVoltage Sensor SBS01V for Futaba Telemetry, 0-100V\u003c\/h1\u003e\n\n\u003cp\u003eVoltage sensor for the Futaba telemetry system on S.BUS2. Suitable for aircraft, helicopter, boat, and car models. Includes 50 cm connection cable and 1A fuse.\u003c\/p\u003e\n\n\u003cp\u003eSuitable transmitters (older transmitters may require the appropriate software version):\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eHandheld Transmitters:\u003c\/b\u003e T4PM, T4PV, T4PLS, T4GRS, T4PX\/R, T6K, T7PX, T7XC, T10J, T12K, T14SG, T16SZ, T18SZ, T18MZ, T32MZ\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTray Transmitters:\u003c\/b\u003e FX-22, FX-32, FX-36\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical Data:\u003c\/b\u003e \u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eMeasurement Range:\u003c\/li\u003e\n\t\u003cli\u003eExternal cable: 0.0 V - 100.0 V \u003c\/li\u003e\n\t\u003cli\u003eInternal cable: 3.7 V - 8.4 V\u003c\/li\u003e\n\t\u003cli\u003eOperating voltage: 3.7 - 7.4 V \u003c\/li\u003e\n\t\u003cli\u003eCurrent consumption: approx. 8 mA \u003c\/li\u003e\n\t\u003cli\u003eDimensions: approx. 40 x 11 x 5 mm \u003c\/li\u003e\n\t\u003cli\u003eWeight: approx. 6 g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FUTABA","offers":[{"title":"Default Title","offer_id":53445690556759,"sku":"MC-SBS-01V","price":50.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/MC-SBS-01V_b1.jpg?v=1779902521"},{"product_id":"spannungssensor-pbs-v60-powerbox","title":"Voltage sensor PBS - V60, Powerbox","description":"\u003ch1\u003e\u003cb\u003eVoltage Sensor PBS - V60, Powerbox\u003c\/b\u003e\u003c\/h1\u003e\n\n\u003cp\u003e\u003cb\u003eProduct Description:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cb\u003ePBS-V60\u003c\/b\u003e is a small and lightweight voltage sensor designed for use with the \u003cb\u003ePowerBox CORE\u003c\/b\u003e, but also for other telemetry systems available on the market. The sensor is simply plugged into the telemetry input of the receiver. A cable is included for connecting to the battery, which is simply soldered or plugged into the battery connector or the balancer plug.\u003c\/p\u003e\n\n\u003cp\u003eThe voltage of a battery is a very reliable indicator of its state of charge. Load and age of the battery have no influence on the voltage threshold at which the battery is empty. Due to its small design and low weight, the \u003cb\u003ePBS-V60\u003c\/b\u003e can also be used for small models.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cb\u003ePBS-V60\u003c\/b\u003e can measure up to 60V; the desired telemetry system can be selected with the \u003cb\u003ePowerBox Terminal\u003c\/b\u003e and the \u003cb\u003eUSB-Interface Adapter\u003c\/b\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eProduct Features:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eVoltage measurement up to 60V\u003c\/li\u003e\n\t\u003cli\u003eSmall design\u003c\/li\u003e\n\t\u003cli\u003eLow weight\u003c\/li\u003e\n\t\u003cli\u003eSupports the following telemetry systems: PowerBox Core, Jeti, Multiplex M-Link, Graupner HoTT, Futaba\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical Data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eOperating voltage: 4.0V - 9.0V\u003c\/li\u003e\n\t\u003cli\u003eCurrent consumption in operation: max 20mA\u003c\/li\u003e\n\t\u003cli\u003eDimensions: 40 x 10 x 4mm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 6g\u003c\/li\u003e\n\t\u003cli\u003eTemperature range: -30°C - +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"PowerBox Systems DEUTSCH","offers":[{"title":"Default Title","offer_id":53445700649303,"sku":"MD6620","price":23.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/MD6620_b1_7df9f24e-7c82-4f73-a3e3-d2d77916e070.jpg?v=1779806710"},{"product_id":"spannungs-sensor-zu-master-telemetrie-empfanger-pichler-c8960","title":"Voltage Sensor for MASTER Telemetry Receiver, Pichler # C8960","description":"\u003ch1 style=\"text-align: center;\"\u003eVoltage Sensor for MASTER Telemetry Receiver\u003cbr\u003e\nPichler # C8960\u003c\/h1\u003e\n\n\u003cp\u003eVoltage sensor, suitable for the MASTER 6K Telemetry receiver.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eMeasurement range: 0 - 100V\u003c\/li\u003e\n\t\u003cli\u003eDimensions: approx. 30 x 15 x 8mm\u003c\/li\u003e\n\t\u003cli\u003eWeight: approx. 6g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PICHLER Modellbau GmbH","offers":[{"title":"Default Title","offer_id":53446004244823,"sku":"PIC8960","price":8.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/PIC8960_b1_3004ac2e-6009-4852-9d5f-09b006eca791.jpg?v=1779812774"},{"product_id":"unilog-stromsensor-80a-mit-mpx-hochstromsteckern-sm-2512","title":"UniLog Current Sensor 80A with MPX high-current connectors, SM # 2512","description":"\u003ch1\u003eUniLog Current Sensor 80A with MPX High-Current Connectors SM # 2512\u003c\/h1\u003e\n\n\u003cp\u003eThe UniLog Current Sensor 80A makes it possible to record drive currents up to 80 amperes. You will also need the UniLog 2 to record the data.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical Data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eMPX high-current plug system\u003c\/li\u003e\n\t\u003cli\u003eMaximum current -10 to +80 Amperes\u003c\/li\u003e\n\t\u003cli\u003eMaximum voltage 60V\u003c\/li\u003e\n\t\u003cli\u003eShunt resistance 1 mOhm\u003c\/li\u003e\n\t\u003cli\u003e11 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448652456279,"sku":"SM2512","price":16.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2512_b1_0a06faba-e79b-4c13-9ea6-31af77c4f8e8.jpg?v=1779817580"},{"product_id":"unilog-stromsensor-150a-mit-4mm-goldkontakt-akku-stecker-sm-2513","title":"UNILog Current Sensor 150A with 4mm Gold Connector (Battery - =Plug), SM # 2513","description":"\u003ch1\u003eUNILog Current Sensor 150A with 4mm Gold Connector (Battery Minus = Plug) SM # 2513\u003c\/h1\u003e\n\n\u003cp\u003ePluggable current and voltage sensor with the following data:\u003cbr\u003e\n \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eConnector system: 4 mm gold\u003c\/li\u003e\n\t\u003cli\u003emaximum current: - 20 A to + 150 A\u003c\/li\u003e\n\t\u003cli\u003emaximum voltage: 60 V\u003c\/li\u003e\n\t\u003cli\u003eMeasuring resistance: 0.5 mOhm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 14 g \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eTo record the data, you need the UNILog 2!\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448653013335,"sku":"SM2513","price":19.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2513_b1_d7782045-714b-4bf3-a2d4-10e08bba30bb.jpg?v=1779817588"},{"product_id":"unilog-stromsensor-150a-mit-5-5mm-goldkontakt-akku-stecker-sm-2514","title":"UNILog Current Sensor 150A with 5.5mm Gold Connector (Battery - =Plug), SM # 2514","description":"\u003ch1\u003eUNILog Current Sensor 150 A with 5.5mm Gold Contact (Battery Minus = Plug) SM # 2514\u003c\/h1\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003ePluggable current and voltage sensor with the following data:\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eConnector system: 5.5 mm gold\u003c\/li\u003e\n\t\u003cli\u003emaximum current: - 20 A to + 150 A\u003c\/li\u003e\n\t\u003cli\u003emaximum voltage: 60 V\u003c\/li\u003e\n\t\u003cli\u003eMeasuring resistance: 0.5 mOhm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 15 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eTo record the data, you need the UNILog 2!\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448653766999,"sku":"SM2514","price":19.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2514_b1_f29363c2-0693-483e-bb1f-e6bb4478a973.jpg?v=1779817598"},{"product_id":"unilog-stromsensor-80a-mit-3-5-mm-goldkontakt-akku-stecker-sm-2515","title":"UNILog Current Sensor 80A with 3.5 mm Gold Contact (Battery - =Plug), SM # 2515","description":"\u003ch1\u003eUNILog Current Sensor 80 A with 3.5 mm Gold Contact (Battery-Minus = Plug) SM # 2515\u003c\/h1\u003e\n\n\u003cp\u003ePlug-in current and voltage sensor with the following data:\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ePlug system: 3.5 mm gold\u003c\/li\u003e\n\t\u003cli\u003emaximum current: - 10 A to + 80 A\u003c\/li\u003e\n\t\u003cli\u003emaximum voltage: 60 V\u003c\/li\u003e\n\t\u003cli\u003eMeasuring resistance: 1 mOhm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 11 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eTo record the data, you need the UNILog 2!\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448655602007,"sku":"SM2515","price":16.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2515_b1_85f29b8b-41db-4fee-9cd3-d19bbf8a2f51.jpg?v=1779817607"},{"product_id":"unilog-stromsensor-150a-mit-6mm-lmt-goldkontakt-akku-stecker-sm-2516","title":"UNILog Current Sensor 150A with 6mm LMT Gold Connector (Battery - =Plug), SM # 2516","description":"\u003ch1\u003eUNILog Current Sensor with 6mm LMT Gold Contact (Battery Minus = Plug) SM # 2516\u003c\/h1\u003e\n\n\u003cp\u003ePluggable current and voltage sensor with the following data:\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ePlug system: 6 mm Gold LMT\u003c\/li\u003e\n\t\u003cli\u003emaximum current: - 20 A to + 150 A\u003c\/li\u003e\n\t\u003cli\u003emaximum voltage: 60 V\u003c\/li\u003e\n\t\u003cli\u003eMeasuring resistance: 0.5 mOhm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 15 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eTo record the data, you need the UNILog 2!\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448656748887,"sku":"SM2516","price":20.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2516_b1_d3471f62-2593-4276-95c1-d255bd6bc0ba.jpg?v=1779817616"},{"product_id":"unilog-stromsensor-400a-mit-6mm-lmt-goldkontakt-akku-stecker-sm-2517","title":"UNILog Current Sensor 400A with 6mm LMT Gold Connector (Battery - = Plug), SM # 2517","description":"\u003ch1\u003eUNILog Current Sensor 400 A with 6mm LMT Gold Contact (Battery Minus = Plug) SM # 2517\u003c\/h1\u003e\n\n\u003cp\u003ePluggable current and voltage sensor with the following data:\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eConnector system: 6 mm Gold LMT\u003c\/li\u003e\n\t\u003cli\u003emaximum current: - 50 A to + 400 A\u003c\/li\u003e\n\t\u003cli\u003emaximum voltage: 60 V\u003c\/li\u003e\n\t\u003cli\u003emeasuring resistance: 0.2 mOhm\u003c\/li\u003e\n\t\u003cli\u003eweight: 18 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eTo record the data, you need the UNILog 2!\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448657535319,"sku":"SM2517","price":23.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2517_b1_cdfdd007-56c3-4881-abee-cb5749d8cc6f.jpg?v=1779817625"},{"product_id":"unilog-empfangerstromsensor-20a-mit-grp-fut-anschlusskabel-sm-2523","title":"UniLog Receiver Current Sensor 20A with Grp.\/Fut. Connection Cable, SM # 2523","description":"\u003ch1\u003eUniLog Receiver Current Sensor 20 A with Grp.\/Fut. Connection Cable SM # 2523\u003c\/h1\u003e\n\n\u003cp\u003ePlug-in current and voltage sensor for measuring the voltage and current consumption of the receiver system. Can be used both between the battery and the receiver, and directly for a single servo.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical Data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eConnection: Uni-connector (Graupner\/Futaba)\u003c\/li\u003e\n\t\u003cli\u003eMax. current measuring range: -5A \/+10A\u003c\/li\u003e\n\t\u003cli\u003eMax. voltage: 10V\u003c\/li\u003e\n\t\u003cli\u003eMeasuring resistance: 4 mOhm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 9g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eScope of delivery: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eCurrent sensor 20 A with Graupner\/Futaba connection cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448659206487,"sku":"SM2523","price":10.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2523_b1_0b5e69a7-7097-4fc1-8cb6-9aa9d20f4431.jpg?v=1779817643"},{"product_id":"unilog-stromsensor-80a-mit-xt-60-goldstecker-sm-2524","title":"UNILog Current Sensor 80A with XT-60 Gold Connector, SM # 2524","description":"\u003ch1\u003eUNILog 80A Current Sensor with XT-60 Gold Connector SM # 2524\u003c\/h1\u003e\n\n\u003cp\u003ePlug-in current and voltage sensor with the following specifications:\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eConnector system: XT60 \u003c\/li\u003e\n\t\u003cli\u003eMaximum current: - 10 A to + 80 A\u003c\/li\u003e\n\t\u003cli\u003eMaximum voltage: 60 V\u003c\/li\u003e\n\t\u003cli\u003eShunt resistance: 1 mOhm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 13 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eTo record the data, you need the UNILog 2!\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448660451671,"sku":"SM2524","price":16.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2524_b1_f7778e8a-f519-45a3-9923-4bb1556ad7ac.jpg?v=1779817652"},{"product_id":"unilog-stromsensor-80a-mit-deans-ultra-sm-2532","title":"UNILog Current Sensor 80A with Deans Ultra, SM # 2532","description":"\u003ch1\u003eUNILog Current Sensor 80A with Deans Ultra SM # 2532\u003c\/h1\u003e\n\n\u003cp\u003ePlug-in current and voltage sensor with the following data:\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical Data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eConnector System: Deans Ultra\u003c\/li\u003e\n\t\u003cli\u003eMaximum Current: - 10 A to + 80 A\u003c\/li\u003e\n\t\u003cli\u003eMaximum Voltage: 60 V\u003c\/li\u003e\n\t\u003cli\u003eMeasuring Resistance: 1 mOhm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 12 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eTo record the data, you will need the UNILog 2!\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448661696855,"sku":"SM2532","price":19.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2532_b1_eb447ef5-ecdd-4bbd-94e0-1c531666808a.jpg?v=1779817662"},{"product_id":"unilog-stromsensor-150a-mit-4mm-goldstecker-akku-stecker-sm-2533","title":"UniLog Current Sensor 150A with 4mm Gold Connector (Battery+ = Connector), SM # 2533","description":"\u003ch1\u003eUniLog Current Sensor 150A with 4mm Gold Connector SM # 2533\u003c\/h1\u003e\n\n\u003cp\u003eThe UniLog Current Sensor 150A allows you to measure drive currents up to 150 Amperes. You will also need the UniLog 2 to record the data.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eATTENTION! This version is ONLY suitable for batteries that have a 4mm gold connector on the positive terminal!\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e4mm connector system\u003c\/li\u003e\n\t\u003cli\u003eCurrent maximum -20 to +150 Amperes\u003c\/li\u003e\n\t\u003cli\u003eVoltage maximum 60V\u003c\/li\u003e\n\t\u003cli\u003eShunt resistor 0.5 mOhm\u003c\/li\u003e\n\t\u003cli\u003e14 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448662614359,"sku":"SM2533","price":19.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2533_b1_aa52be9b-3043-4ce9-9cbe-1db0148a4857.jpg?v=1779817671"},{"product_id":"unilog-stromsensor-80a-mit-3-5mm-goldsteckern-akku-stecker-sm-2535","title":"UniLog Current Sensor 80A with 3.5mm Gold Connectors (Battery+ = Plug), SM # 2535","description":"\u003ch1\u003eUniLog Current Sensor 80A with 3.5mm Gold Connectors SM # 2535\u003c\/h1\u003e\n\n\u003cp\u003eWith the UniLog Current Sensor 80A, it is possible to measure drive currents of up to 80 amperes. You will also need the UniLog 2 to record the data.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eATTENTION! This version is ONLY suitable for batteries that have a 3.5mm gold connector on the positive terminal!\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e3.5mm connector system\u003c\/li\u003e\n\t\u003cli\u003eCurrent maximum -10 to +80 Amperes\u003c\/li\u003e\n\t\u003cli\u003eVoltage maximum 60V\u003c\/li\u003e\n\t\u003cli\u003eMeasuring resistance 1 mOhm\u003c\/li\u003e\n\t\u003cli\u003e11 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448663138647,"sku":"SM2535","price":16.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2535_b1_4490efc5-0a9c-4ff3-a346-844685c575aa.jpg?v=1779817680"},{"product_id":"unilog-stromsensor-400a-mit-6mm-lmt-goldkontakt-akku-buchse-sm-2537","title":"UNILog Current Sensor 400A with 6mm LMT Gold Connector (Battery - = Female), SM # 2537","description":"\u003ch1\u003eUNILog Current Sensor 400 A with 6mm LMT Gold Contact (Battery-Minus = Socket) SM # 2537\u003c\/h1\u003e\n\n\u003cp\u003ePluggable current and voltage sensor with the following data:\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ePlug system: 6 mm Gold LMT\u003c\/li\u003e\n\t\u003cli\u003emaximum current: - 50 A to + 400 A\u003c\/li\u003e\n\t\u003cli\u003emaximum voltage: 60 V\u003c\/li\u003e\n\t\u003cli\u003eMeasuring resistance: 0.2 mOhm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 18 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eTo record the data, you need the UNILog 2!\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448663499095,"sku":"SM2537","price":23.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM2537_b1_6a4b2382-d9d8-4693-8232-ef03b29e2052.jpg?v=1779817690"},{"product_id":"unisens-e-mit-mpx-steckverbindung-grun-sm-modellbau-3100","title":"UniSens-E with MPX Connector green, SM-Modellbau # 3100","description":"\u003ch1\u003eUniSens-E with MPX plug connection green SM # 3100\u003c\/h1\u003e\n\n\u003cp\u003eWith improved altitude sensor V2 The small, powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless speed \/ altitude \/ variometer\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a pure telemetry sensor especially for all electric models. It is so small and light, yet so powerful, that it can be used in almost any model. In accordance with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest and JR DMSS. The UniSens-E automatically recognizes HoTT telemetry systems when delivered. When used with Jeti, Multiplex, Futaba or JR, the telemetry must be specified in the settings beforehand. To change the settings via PC or for firmware updates, a suitable USB interface such as item no. 2550 or an existing USB connection cable from Jeti, Multiplex or Graupner is required. See the instructions for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire drive, i.e. voltage, current, capacity and even speed. A brushless speed sensor is already built in as a special feature. To measure the speed, only a small cable connection to one of the three motor phases needs to be made with the enclosed cable. Since a barometric (air pressure) altitude sensor with high resolution is also integrated, a variometer is also realized with the UniSens-E in addition to altitude measurement. Extensive alarms can also be programmed, which are reported via telemetry via the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various plug systems, so that usually nothing has to be soldered. The current measurement range extends symmetrically in both directions. This means that the pin assignment, i.e. whether the battery has male or female on the positive pole, does not matter. The measuring direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live directly via our UniDisplay and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether glider, aerobatic aircraft, helicopter, HLG or slow flyer, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for model aircraft. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful universal RC telemetry sensor in all respects, which utilizes the possibilities of modern electronics to be a great help to you in dealing with your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecomplete measurement of electric drives with current, voltage, power, capacity, speed and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eintegrated brushless speed sensor\u003c\/li\u003e\n\t\u003cli\u003efull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, FrSky and Spektrum\u003c\/li\u003e\n\t\u003cli\u003ebarometric variometer\u003c\/li\u003e\n\t\u003cli\u003ecurrent measuring range up to 140 A in both directions, voltage up to 60 V (however, the maximum current carrying capacity of the plugs used must not be exceeded!)\u003c\/li\u003e\n\t\u003cli\u003econnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003edirect connection to GPS logger possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003emeasurement of receiver battery voltage\u003c\/li\u003e\n\t\u003cli\u003epower supply via receiver\u003c\/li\u003e\n\t\u003cli\u003ecurrent status is signaled via LED\u003c\/li\u003e\n\t\u003cli\u003edirect viewing of measured values live or recorded with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eparameter settings via PC, UniDisplay and telemetry possible\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool)\u003c\/li\u003e\n\t\u003cli\u003efree firmware updates via PC with our USB interface (item no. 2550) or with existing USB connection cables from Jeti, Multiplex or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003ecan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003ePlease refer to the operating manual for technical data and the complete range of functions.\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. altitude measurement only with altitude sensor already integrated in the UniSens-E Application e.g. in F3B \/ F3J glider\u003c\/p\u003e\n\n\u003cp\u003e2. electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecurrent measuring range: 140 A in both directions, i.e. - 140 A to + 140 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 100 A unlimited - 120 A for 1 minute - 140 A for 20 seconds (However, depending on the plug system, the limits of the plugs are significantly lower!) Useful values are with - MPX green (double contact) and XT60 continuous: 50 A \/ 20A\u003c\/li\u003e\n\t\u003cli\u003evoltage measuring range: 0 to 60V\u003c\/li\u003e\n\t\u003cli\u003ealtitude measuring range: 0 to 8000 m above sea level, automatically reset to zero when switched on\u003c\/li\u003e\n\t\u003cli\u003ereceiver voltage measurement: 3.8 to 10V\u003c\/li\u003e\n\t\u003cli\u003edata rate: 10Hz\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver power supply via the telemetry connection (from 3.8V to a maximum of 10V)\u003c\/li\u003e\n\t\u003cli\u003ecurrent consumption: approx. 25mA\u003c\/li\u003e\n\t\u003cli\u003eexternal connections: 1 connection for telemetry and power supply 1 phase connection for brushless speed measurement 1 servo pulse input from receiver COM connection for UniDisplay, GPS logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003egreen MPX connector: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eyellow XT60 connector: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold connector: 26 (55) x 22 x 9 mm 5.5 mm gold connector: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold connector: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eweight: 10 -14g without cable (depending on plug system), connection cable 4g\u003c\/li\u003e\n\t\u003cli\u003escope of delivery: UniSens-E with integrated altitude sensor, variometer connection cable to the receiver for telemetry\/power supply, connection cable for brushless speed measurement, detailed color operating manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448679850327,"sku":"SM3100","price":55.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3100_b1_429e289b-d21d-42de-934f-e62e02f7cd03.jpg?v=1782129313"},{"product_id":"unisens-e-mit-xt-60-steckverbindung-sm-modellbau-3101","title":"UniSens-E with XT-60 connector, SM-Modellbau # 3101","description":"\u003ch1\u003eUniSens-E with XT-60 Plug Connection SM # 3101\u003c\/h1\u003e\n\n\u003cp\u003eWith improved altitude sensor V2 The small, powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless speed \/ altitude \/ Vario\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a pure telemetry sensor specifically for all electric models. It is so small and light, yet so powerful, that it can be used in almost any model. In accordance with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest, and JR DMSS. The UniSens-E automatically recognizes HoTT telemetry systems upon delivery. When used with Jeti, Multiplex, Futaba, or JR, the telemetry must be set in advance in the settings. To change settings via PC or for firmware updates, a suitable USB interface such as order no. 2550 or an existing USB connection cable from Jeti, Multiplex, or Graupner is required. Please refer to the manual for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire drive, including voltage, current, capacity, and even speed. A special feature is that a brushless speed sensor is already permanently installed. To measure the speed, only a small cable connection to one of the three motor phases needs to be made with the included cable. Since a barometric (air pressure) altitude sensor with high resolution is also integrated, a Vario function is also realized with the UniSens-E in addition to altitude measurement. Extensive alarms can also be programmed, which are reported via telemetry through the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various plug systems, so that no soldering is usually required. The current measuring range extends symmetrically in both directions. This means that the plug assignment, i.e. whether the battery has a male or female connector on the positive pole, does not matter. The measuring direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live directly via our UniDisplay, and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether glider, aerobatic aircraft, helicopter, HLG or slow flyer, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for model aircraft. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful, universal RC telemetry sensor in all respects, which utilizes the possibilities of modern electronics to be a great help to you as a small helper in dealing with your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecomplete measurement of electric drives with current, voltage, power, capacity, speed, and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eintegrated brushless speed sensor\u003c\/li\u003e\n\t\u003cli\u003efull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, FrSky, and Spektrum\u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement with automatic zeroing after power-on, barometric Vario\u003c\/li\u003e\n\t\u003cli\u003ecurrent measuring range up to 140 A in both directions, voltage up to 60 V (however, the maximum current carrying capacity of the connectors used must not be exceeded!)\u003c\/li\u003e\n\t\u003cli\u003econnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003edirect connection to GPS logger possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003emeasurement of receiver battery voltage\u003c\/li\u003e\n\t\u003cli\u003epower supply by receiver\u003c\/li\u003e\n\t\u003cli\u003ecurrent status is signaled via LED\u003c\/li\u003e\n\t\u003cli\u003edirect viewing of measured values live or recorded with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eparameter settings possible via PC, UniDisplay, and telemetry\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool)\u003c\/li\u003e\n\t\u003cli\u003efree firmware updates via PC with our USB interface (order no. 2550) or with existing USB connection cables such as those from Jeti, Multiplex or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003ecan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003ePlease refer to the operating manual for technical data and the complete range of functions.\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. Altitude measurement only with altitude sensor already integrated in UniSens-E, e.g. in F3B \/ F3J glider\u003c\/p\u003e\n\n\u003cp\u003e2. Electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eCurrent measuring range: 140 A in both directions, i.e. - 140 A to + 140 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 100 A unlimited - 120 A for 1 minute - 140 A for 20 seconds (However, depending on the plug system, the limits of the plugs are significantly lower!) Meaningful values are with - MPX green (double contact) and XT60 continuous: 50 A \/ 20A\u003c\/li\u003e\n\t\u003cli\u003eVoltage measuring range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003eAltitude measuring range: 0 to 8000 m above sea level, automatically zeroed when switched on\u003c\/li\u003e\n\t\u003cli\u003eReceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003eData rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003ePower supply from receiver supply via the telemetry connection (from 3.8 V to a maximum of 10 V)\u003c\/li\u003e\n\t\u003cli\u003eCurrent consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eexternal connections: 1 connection for telemetry and power supply, 1 phase connection for brushless speed measurement, 1 servo pulse input from receiver, COM connection for UniDisplay, GPS logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003egreen MPX plug: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eyellow XT60 plug: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold plug: 26 (55) x 22 x 9 mm, 5.5 mm gold plug: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold plug: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 10 g - 14 g without cable (depending on plug system), connection cable 4 g\u003c\/li\u003e\n\t\u003cli\u003eScope of delivery: UniSens-E with integrated altitude sensor \/ Vario connection cable to the receiver for telemetry \/ power supply, connection cable for brushless speed measurement, detailed color operating manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448680538455,"sku":"SM3101","price":55.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3101_b1.jpg?v=1780061366"},{"product_id":"unisens-e-mit-4mm-goldkontaktsteckverbindung-sm-modellbau-3102","title":"UniSens-E with 4mm gold-plated connector, SM-Modellbau # 3102","description":"\u003ch1\u003eUniSens-E with 4mm gold connector SM # 3102\u003c\/h1\u003e\n\n\u003cp\u003eWith improved V2 altitude sensor. The small, powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless RPM \/ altitude \/ variometer.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a pure telemetry sensor specifically for all electric models. It is so small and light, yet so powerful that it can be used in almost any model. In accordance with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest, and JR DMSS. The UniSens-E automatically recognizes HoTT telemetry systems when delivered. When used with Jeti, Multiplex, Futaba, or JR, the telemetry must be specified in the settings beforehand. To change settings via PC or for firmware updates, a suitable USB interface such as item no. 2550 or an existing USB connection cable from Jeti, Multiplex, or Graupner is required. Please refer to the manual for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire drive system, i.e., voltage, current, capacity, and even RPM. A brushless RPM sensor is already built in as a special feature. To measure the RPM, only a small cable connection to one of the three motor phases needs to be made with the enclosed cable. Since a barometric (air pressure) altitude sensor with high resolution is also integrated, in addition to altitude measurement, a variometer is also realized with the UniSens-E. Extensive alarms can also be programmed, which are reported via telemetry through the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various connector systems, so soldering is usually not necessary. The current measurement range extends symmetrically in both directions. This means that the connector assignment, i.e., whether the battery has male or female on the positive pole, does not matter. The measurement direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live directly via our UniDisplay, and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether glider, aerobatic aircraft, helicopter, HLG, or slow flyer, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for flight models. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful universal RC telemetry sensor in all respects, which utilizes the possibilities of modern electronics to be a great help to you as a small helper in dealing with your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eComplete measurement of electric drives with current, voltage, power, capacity, RPM, and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eIntegrated brushless RPM sensor\u003c\/li\u003e\n\t\u003cli\u003eFull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, Fr Sky, and Spektrum\u003c\/li\u003e\n\t\u003cli\u003eAltitude measurement with automatic zeroing after power-on, barometric variometer\u003c\/li\u003e\n\t\u003cli\u003eCurrent measurement range up to 140 A in both directions, voltage up to 60 V (however, the maximum current carrying capacity of the connectors used must not be exceeded!)\u003c\/li\u003e\n\t\u003cli\u003eConnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003eDirect connection to GPS logger possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003eMeasurement of receiver battery voltage\u003c\/li\u003e\n\t\u003cli\u003ePower supply by receiver\u003c\/li\u003e\n\t\u003cli\u003eCurrent status is signaled via LED\u003c\/li\u003e\n\t\u003cli\u003eDirect viewing of measured values live or recorded with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eParameter settings possible via PC, UniDisplay, and telemetry\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool)\u003c\/li\u003e\n\t\u003cli\u003eFree firmware updates via PC with our USB interface (item no. 2550) or with existing USB connection cables from Jeti, Multiplex, or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003eCan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eFor technical data and the complete range of functions, please refer to the operating instructions.\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. Altitude measurement only with altitude sensor integrated in UniSens-E, e.g., for F3B \/ F3J gliders\u003c\/p\u003e\n\n\u003cp\u003e2. Electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eCurrent measurement range: 140 A in both directions, i.e., -140 A to +140 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 100 A unlimited - 120 A for 1 minute - 140 A for 20 seconds (However, depending on the connector system, the limits of the connectors are significantly lower!) Useful values are with - MPX green (double contact) and XT60 continuous: 50 A \/ 20A\u003c\/li\u003e\n\t\u003cli\u003eVoltage measurement range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003eAltitude measurement range: 0 to 8000 m above sea level, automatically zeroed when switched on\u003c\/li\u003e\n\t\u003cli\u003eReceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003eData rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003ePower supply from receiver power supply via the telemetry connection (from 3.8 V to a maximum of 10 V)\u003c\/li\u003e\n\t\u003cli\u003ePower consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eExternal connections: 1 connection for telemetry and power supply 1 phase connection for brushless RPM measurement 1 servo pulse input from the receiver COM connection for UniDisplay, GPS logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eGreen MPX connector: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eYellow XT60 connector: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold connector: 26 (55) x 22 x 9 mm 5.5 mm gold connector: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold connector: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 10 g - 14 g without cable (depending on connector system), connection cable 4 g\u003c\/li\u003e\n\t\u003cli\u003eScope of delivery: UniSens-E with integrated altitude sensor \/ variometer Connection cable to receiver for telemetry \/ power supply Connection cable for brushless RPM measurement Detailed color operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448681357655,"sku":"SM3102","price":55.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3102_b1_486bc1af-6802-4565-b5c2-b861601d2d27.jpg?v=1782379314"},{"product_id":"unisens-e-mit-5-5mm-goldkontaktsteckverbindung-sm-modellbau-3103","title":"UniSens-E with 5.5mm gold-plated connector, SM-Modellbau # 3103","description":"\u003ch1\u003eUniSens-E with 5.5mm gold connector SM # 3103\u003c\/h1\u003e\n\n\u003cp\u003eWith improved V2 altitude sensor. The small yet powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless RPM \/ altitude \/ variometer\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a pure telemetry sensor specifically for all electric models. It is so small and light, yet so powerful, that it can be used in almost any model. In line with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest and JR DMSS. The UniSens-E automatically recognizes HoTT telemetry systems upon delivery. When used with Jeti, Multiplex, Futaba or JR, the telemetry must be pre-set in the settings. To change settings via PC or for firmware updates, a suitable USB interface such as item no. 2550 or an existing USB connection cable from Jeti, Multiplex or Graupner is required. Please refer to the manual for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire drive system, i.e. voltage, current, capacity and even RPM. A brushless RPM sensor is already built-in as a special feature. To measure the RPM, only a small cable connection to one of the three motor phases with the enclosed cable needs to be established. Since a barometric (air pressure) altitude sensor with high resolution is also integrated, in addition to altitude measurement, a variometer is also realized with the UniSens-E. Extensive alarms can also be programmed, which are reported via telemetry through the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various connector systems, so that normally no soldering is required. The current measuring range extends symmetrically in both directions. This means that the connector assignment, i.e. whether the battery has male or female on the positive pole, does not matter. The measuring direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live via our UniDisplay and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether glider, aerobatic aircraft, helicopter, HLG or slow flyer, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for model aircraft. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful universal RC telemetry sensor in all respects, which utilizes the possibilities of modern electronics to be a great help to you as a small helper in dealing with your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecomplete measurement of electric drives with current, voltage, power, capacity, RPM and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eintegrated brushless RPM sensor\u003c\/li\u003e\n\t\u003cli\u003efull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, FrSky and Spektrum\u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement with automatic zeroing after power-on barometric variometer\u003c\/li\u003e\n\t\u003cli\u003ecurrent measuring range up to 140 A in both directions, voltage up to 60 V (however, the maximum current carrying capacity of the connectors used must not be exceeded!)\u003c\/li\u003e\n\t\u003cli\u003econnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003edirect connection to GPS logger possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003ereceiver battery voltage measurement\u003c\/li\u003e\n\t\u003cli\u003epower supply by receiver\u003c\/li\u003e\n\t\u003cli\u003ecurrent status is signaled by LED\u003c\/li\u003e\n\t\u003cli\u003edirect viewing of measured values live or recorded with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eparameter settings via PC, UniDisplay and telemetry possible\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool)\u003c\/li\u003e\n\t\u003cli\u003efree firmware updates via PC with our USB interface (item no. 2550) or with existing USB connection cables from Jeti, Multiplex or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003ecan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eFor technical data and the complete range of functions, please refer to the operating manual. \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. altitude measurement only with altitude sensor integrated in the UniSens-E, e.g. in F3B \/ F3J gliders\u003c\/p\u003e\n\n\u003cp\u003e2. electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecurrent measuring range: 140 A in both directions, i.e. - 140 A to + 140 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permitted: - 100 A unlimited - 120 A for 1 minute - 140 A for 20 seconds (However, depending on the connector system, the limits of the connectors are significantly lower!) Useful values are with - MPX green (double contact) and XT60 continuous: 50 A \/ 20A \u003c\/li\u003e\n\t\u003cli\u003evoltage measuring range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003ealtitude measuring range: 0 to 8000 m above sea level, automatically zeroed when switched on\u003c\/li\u003e\n\t\u003cli\u003ereceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003edata rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver power supply via the telemetry connection (from 3.8 V to a maximum of 10 V)\u003c\/li\u003e\n\t\u003cli\u003epower consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eexternal connections: 1 connection for telemetry and power supply 1 phase connection for brushless RPM measurement 1 servo pulse input from receiver COM connection for UniDisplay, GPS logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003egreen MPX connector: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eyellow XT60 connector: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold connector: 26 (55) x 22 x 9 mm 5.5 mm gold connector: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold connector: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eweight: 10 g - 14 g without cable (depending on connector system), connection cable 4 g\u003c\/li\u003e\n\t\u003cli\u003escope of delivery: UniSens-E with integrated altitude sensor \/ vario connection cable to the receiver for telemetry \/ power supply connection cable for brushless RPM measurement detailed colored operating manual \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448682537303,"sku":"SM3103","price":55.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3103_b1.jpg?v=1781086739"},{"product_id":"unisens-e-mit-6-mm-lmt-goldkontaktsteckverbindung-sm-modellbau-3104","title":"UniSens-E with 6mm LMT Gold Contact Plug, SM-Modellbau # 3104","description":"\u003ch1\u003eUniSens-E with 6mm gold connector SM # 3104\u003c\/h1\u003e\n\n\u003cp\u003eWith improved altitude sensor V2 The small, powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless speed \/ altitude \/ Vario\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a pure telemetry sensor specially designed for all electric models. It is so small and light, yet so powerful that it can be used in almost any model. In line with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest and JR DMSS. The UniSens-E automatically detects HoTT telemetry systems when delivered. When used with Jeti, Multiplex, Futaba or JR, the telemetry must be specified in the settings beforehand. To change settings via PC or for firmware updates, a suitable USB interface such as item no. 2550 or an existing USB connection cable from Jeti, Multiplex or Graupner is required. Please refer to the manual for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire drive, i.e. voltage, current, capacity and even speed. A brushless speed sensor is already permanently installed as a special highlight. For speed measurement, only a small cable connection to one of the three motor phases needs to be made with the enclosed cable. Since a barometric (air pressure) altitude sensor with high resolution is also integrated, a Vario is also realized with the UniSens-E in addition to altitude measurement. Extensive alarms can also be programmed, which are reported via telemetry via the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various connector systems, so that no soldering is usually necessary. The current measuring range extends symmetrically in both directions. This means that the connector assignment, i.e. whether the battery has a male or female connector on the positive pole, does not matter. The measuring direction is simply set in the setup. Via our UniDisplay, all measured values of the UniSens-E can also be viewed live and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether gliders, aerobatic aircraft, helicopters, HLG or slow flyers, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for model aircraft. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful universal RC telemetry sensor in all respects, which utilizes the possibilities of modern electronics to be a great help to you as a small helper in dealing with your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecomplete measurement of electric drives with current, voltage, power, capacity, speed and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eintegrated brushless speed sensor\u003c\/li\u003e\n\t\u003cli\u003efull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, Fr Sky and Spektrum\u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement with automatic zeroing after switching on barometric Vario\u003c\/li\u003e\n\t\u003cli\u003ecurrent measuring range up to 140 A in both directions, voltage up to 60 V (the maximum current carrying capacity of the connectors used must not be exceeded!)\u003c\/li\u003e\n\t\u003cli\u003econnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003edirect connection to the GPS logger possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003emeasurement of receiver battery voltage\u003c\/li\u003e\n\t\u003cli\u003epower supply by receiver\u003c\/li\u003e\n\t\u003cli\u003ecurrent status is signaled by LED\u003c\/li\u003e\n\t\u003cli\u003edirect viewing of live or recorded measured values with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eparameter settings via PC, UniDisplay and telemetry possible\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool)\u003c\/li\u003e\n\t\u003cli\u003efree firmware updates via PC with our USB interface (item no. 2550) or with existing USB connection cables such as from Jeti, Multiplex or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003ecan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003ePlease refer to the operating manual for technical data and the complete range of functions.\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. only altitude measurement with altitude sensor already integrated in UniSens-E, e.g. in F3B \/ F3J gliders\u003c\/p\u003e\n\n\u003cp\u003e2. electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecurrent measuring range: 140 A in both directions, i.e. - 140 A to + 140 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 100 A unlimited - 120 A for 1 minute - 140 A for 20 seconds (Depending on the connector system, however, the limits of the connectors are significantly lower!) Useful values are with - MPX green (double contact) and XT60 continuous: 50 A \/ 20A\u003c\/li\u003e\n\t\u003cli\u003evoltage measuring range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003ealtitude measuring range: 0 to 8000 m above sea level, automatically zeroed when switched on\u003c\/li\u003e\n\t\u003cli\u003ereceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003edata rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver power supply via the telemetry connection (from 3.8 V to a maximum of 10 V)\u003c\/li\u003e\n\t\u003cli\u003epower consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eexternal connections: 1 x connection for telemetry and power supply 1 x phase connection for brushless speed measurement 1 x servo pulse input from the receiver COM connection for UniDisplay, GPS logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003egreen MPX connector: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eyellow XT60 connector: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold connector: 26 (55) x 22 x 9 mm 5.5 mm gold connector: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold connector: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 10 g - 14 g without cable (depending on the connector system), connection cable 4 g\u003c\/li\u003e\n\t\u003cli\u003eScope of delivery: UniSens-E with integrated altitude sensor \/ Vario connection cable to the receiver for telemetry \/ power supply connection cable for brushless speed measurement detailed color operating manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448685650263,"sku":"SM3104","price":57.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3104_b1_d0f31e70-93d8-42e7-a68e-38e535db1e1f.jpg?v=1779817826"},{"product_id":"unisens-e-mit-4mm-silikonkabel-sm-modellbau-3105","title":"UniSens-E with 4mm² silicone cable, SM-Modellbau # 3105","description":"\u003ch1\u003eUniSens-E with 4mm silicone cable SM # 3105 \u003c\/h1\u003e\n\n\u003cp\u003eWith improved altitude sensor V2 The small, powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless speed \/ altitude \/ Vario\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a pure telemetry sensor specifically for all electric models. It is so small and light, yet so powerful, that it can be used in almost any model. In line with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest and JR DMSS. The UniSens-E automatically recognizes HoTT telemetry systems when delivered. When used with Jeti, Multiplex, Futaba or JR, the telemetry must be specified in the settings beforehand. To change settings via PC or for firmware updates, a suitable USB interface such as item no. 2550 or an existing USB connection cable from Jeti, Multiplex or Graupner is required. Please refer to the manual for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire drive, i.e. voltage, current, capacity and even speed. A brushless speed sensor is already built in as a special feature. To measure the speed, only a small cable connection to one of the three motor phases needs to be made with the enclosed cable. Since a barometric (air pressure) altitude sensor with high resolution is also integrated, an altimeter and a vario are realized with the UniSens-E. Extensive alarms can also be programmed, which are reported via telemetry via the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various connector systems, so that no soldering is usually necessary. The current measuring range extends symmetrically in both directions. This means that the connector assignment, i.e. whether the battery has male or female on the positive pole, does not matter. The measuring direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live directly via our UniDisplay and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether gliders, aerobatic aircraft, helicopters, HLGs or slow-flyers, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for model aircraft. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful, universal RC telemetry sensor in all respects that utilizes the possibilities of modern electronics to be a great help to you as a small helper in handling your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecomplete measurement of electric drives with current, voltage, power, capacity, speed and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eintegrated brushless speed sensor\u003c\/li\u003e\n\t\u003cli\u003efull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, Fr Sky and Spektrum \u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement with automatic zeroing after switching on barometric vario\u003c\/li\u003e\n\t\u003cli\u003ecurrent measuring range up to 140 A in both directions, voltage up to 60 V (however, the maximum current carrying capacity of the connectors used must not be exceeded!)\u003c\/li\u003e\n\t\u003cli\u003econnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003edirect connection to GPS logger possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003emeasurement of receiver battery voltage\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver\u003c\/li\u003e\n\t\u003cli\u003ecurrent status is signaled via LED\u003c\/li\u003e\n\t\u003cli\u003edirect viewing of measured values live or recorded with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eparameter settings possible via PC, UniDisplay and telemetry\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool) \u003c\/li\u003e\n\t\u003cli\u003efree firmware updates via PC with our USB interface (item no. 2550) or with existing USB connection cables such as from Jeti, Multiplex or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003ecan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003ePlease refer to the operating manual for technical data and the complete range of functions. \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. altitude measurement only with altitude sensor already integrated in UniSens-E, e.g. in F3B \/ F3J gliders\u003c\/p\u003e\n\n\u003cp\u003e2. electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecurrent measuring range: 140 A in both directions, i.e. - 140 A to + 140 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 100 A unlimited - 120 A for 1 minute - 140 A for 20 seconds (However, depending on the plug system, the limits of the plugs are significantly lower!) Meaningful values are with - MPX green (double contact) and XT60 continuous: 50 A \/ 20A \u003c\/li\u003e\n\t\u003cli\u003evoltage measuring range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003ealtitude measuring range: 0 to 8000 m above sea level, automatically zeroed when switched on\u003c\/li\u003e\n\t\u003cli\u003ereceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003edata rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver power supply via the telemetry connection (from 3.8 V to a maximum of 10 V)\u003c\/li\u003e\n\t\u003cli\u003ecurrent consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eexternal connections: 1 connection for telemetry and power supply 1 phase connection for brushless speed measurement 1 servo pulse input from receiver COM connection for UniDisplay, GPS logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003egreen MPX connector: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eyellow XT60 connector: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold connector: 26 (55) x 22 x 9 mm 5.5 mm gold connector: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold connector: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eweight: 10 g - 14 g without cable (depending on plug system), connection cable 4 g\u003c\/li\u003e\n\t\u003cli\u003escope of delivery: UniSens-E with integrated altitude sensor \/ vario connection cable to the receiver for telemetry \/ power supply connection cable for brushless speed measurement detailed color operating manual \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448686371159,"sku":"SM3105","price":55.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3105_b1.jpg?v=1781115815"},{"product_id":"unisens-e-mit-xt-90-sm-modellbau-3106","title":"UniSens-E with XT-90, SM-Modellbau # 3106","description":"\u003ch1\u003eUniSens-E with XT-90 plug connection SM # 3106 \u003c\/h1\u003e\n\n\u003cp\u003eWith improved altitude sensor V2, the small, powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless RPM \/ altitude \/ Vario\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a pure telemetry sensor specifically for all electric models. It is so small and lightweight, yet so powerful that it can be used in almost any model. In line with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest and JR DMSS. The UniSens-E automatically recognizes HoTT telemetry systems when delivered. When used with Jeti, Multiplex, Futaba or JR, the telemetry must be specified in the settings beforehand. To change settings via PC or for firmware updates, a suitable USB interface such as item no. 2550 or an existing USB connection cable such as from Jeti, Multiplex or Graupner is required. Please refer to the manual for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the complete drive system, i.e. voltage, current, capacity and even RPM. A special feature is that a brushless RPM sensor is already built in. To measure the RPM, only a small cable connection to one of the three motor phases needs to be made with the enclosed cable. Since a barometric (air pressure) altitude sensor with high resolution is also integrated, an altimeter and a vario are realized with the UniSens-E. Extensive alarms can also be programmed, which are reported via telemetry via the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various plug systems, so that no soldering is usually required. The current measuring range extends symmetrically in both directions. This means that the plug assignment, i.e. whether the battery has male or female on the positive pole, does not matter. The measuring direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live directly via our UniDisplay and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether gliders, aerobatic aircraft, helicopters, HLGs or slow flyers, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for flight models. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful, universal RC telemetry sensor in all respects, which uses the possibilities of modern electronics to be a great help to you as a small helper in dealing with your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecomplete measurement of electric drives with current, voltage, power, capacity, RPM and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eintegrated brushless RPM sensor\u003c\/li\u003e\n\t\u003cli\u003efull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, Fr Sky and Spektrum \u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement with automatic zeroing after power-on barometric vario\u003c\/li\u003e\n\t\u003cli\u003ecurrent measuring range up to 140 A in both directions, voltage up to 60 V (the maximum current carrying capacity of the plugs used must not be exceeded!)\u003c\/li\u003e\n\t\u003cli\u003econnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003edirect connection to GPS logger possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003emeasurement of receiver battery voltage\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver\u003c\/li\u003e\n\t\u003cli\u003ecurrent status is signaled via LED\u003c\/li\u003e\n\t\u003cli\u003edirect viewing of measured values live or recorded with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eparameter settings possible via PC, UniDisplay and telemetry\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool) \u003c\/li\u003e\n\t\u003cli\u003efree firmware updates via PC with our USB interface (item no. 2550) or with existing USB connection cables such as from Jeti, Multiplex or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003ecan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003ePlease refer to the operating instructions for technical data and the complete range of functions. \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. altitude measurement only with altitude sensor already integrated in UniSens-E, e.g. in F3B \/ F3J gliders\u003c\/p\u003e\n\n\u003cp\u003e2. electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecurrent measuring range: 140 A in both directions, i.e. - 140 A to + 140 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 100 A unlimited - 120 A for 1 minute - 140 A for 20 seconds (However, depending on the plug system, the limits of the plugs are significantly lower!) Useful values are with - MPX green (double contact) and XT60 continuous: 50 A \/ 20A \u003c\/li\u003e\n\t\u003cli\u003evoltage measuring range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003ealtitude measuring range: 0 to 8000 m above sea level, automatically zeroed when switched on\u003c\/li\u003e\n\t\u003cli\u003ereceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003edata rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver supply via the telemetry connection (from 3.8 V to a maximum of 10 V)\u003c\/li\u003e\n\t\u003cli\u003epower consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eexternal connections: 1 connection for telemetry and power supply 1 phase connection for brushless RPM measurement 1 servo pulse input from receiver COM connection for UniDisplay, GPS logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003egreen MPX plug: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eyellow XT60 plug: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold plug: 26 (55) x 22 x 9 mm 5.5 mm gold plug: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold plug: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003emass: 10 g - 14 g without cable (depending on plug system), connection cable 4 g\u003c\/li\u003e\n\t\u003cli\u003escope of delivery: UniSens-E with integrated altitude sensor \/ vario connection cable to the receiver for telemetry \/ power supply connection cable for brushless RPM measurement detailed color operating instructions \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448686928215,"sku":"SM3106","price":55.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3106_b1.jpg?v=1779935491"},{"product_id":"unisens-e-mit-xt-30-steckverbinder-max-45a-sm-modellbau-3107","title":"UniSens-E with XT-30 connector, max. 45A, SM-Modellbau # 3107","description":"\u003ch1\u003eUniSens-E with XT-30 Connector SM # 3107\u003c\/h1\u003e\n\n\u003cp\u003eWith improved V2 altitude sensor. The small, powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless RPM \/ altitude \/ variometer.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a pure telemetry sensor specifically for all electric models. It is so small and light, yet so powerful, that it can be used in almost any model. In line with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest, and JR DMSS. Out of the box, the UniSens-E automatically detects HoTT telemetry systems. When used with Jeti, Multiplex, Futaba, or JR, the telemetry system must be pre-selected in the settings. To change settings via PC or for firmware updates, a suitable USB interface like item no. 2550 or an existing USB connection cable from Jeti, Multiplex, or Graupner is required. Please refer to the manual for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire drive system, including voltage, current, capacity, and even RPM. A brushless RPM sensor is already built-in as a special feature. To measure RPM, only a small cable connection to one of the three motor phases needs to be made using the included cable. Since a barometric (air pressure) altimeter sensor with high resolution is also integrated, an altimeter and a variometer are realized with the UniSens-E. Extensive alarms can also be programmed, which are reported via telemetry through the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various connector systems, so soldering is usually not necessary. The current measurement range extends symmetrically in both directions. This means the pin assignment, i.e., whether the battery has a male or female connector on the positive pole, does not matter. The measurement direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live directly via our UniDisplay, and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether gliders, aerobatic aircraft, helicopters, HLGs, or slow flyers, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for model aircraft. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful, universal RC telemetry sensor in all respects, which utilizes the possibilities of modern electronics to be a great help to you in dealing with your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eComplete measurement of electric drives with current, voltage, power, capacity, RPM, and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eIntegrated brushless RPM sensor\u003c\/li\u003e\n\t\u003cli\u003eFull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, FrSky, and Spektrum\u003c\/li\u003e\n\t\u003cli\u003eAltitude measurement with automatic zeroing after power-on, barometric variometer\u003c\/li\u003e\n\t\u003cli\u003eCurrent measurement range up to 140 A in both directions, voltage up to 60 V (however, the maximum current carrying capacity of the connectors used must not be exceeded!)\u003c\/li\u003e\n\t\u003cli\u003eConnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003eDirect connection to GPS logger possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003eMeasurement of receiver battery voltage\u003c\/li\u003e\n\t\u003cli\u003ePower supply via receiver\u003c\/li\u003e\n\t\u003cli\u003eCurrent status signaled by LED\u003c\/li\u003e\n\t\u003cli\u003eDirect viewing of measured values live or recorded with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eParameter settings possible via PC, UniDisplay, and telemetry\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool)\u003c\/li\u003e\n\t\u003cli\u003eFree firmware updates via PC with our USB interface (item no. 2550) or with existing USB connection cables from Jeti, Multiplex, or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003eCan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003ePlease refer to the operating manual for technical data and the complete range of functions.\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. Altitude measurement only with altitude sensor already integrated in the UniSens-E, e.g., for F3B \/ F3J gliders\u003c\/p\u003e\n\n\u003cp\u003e2. Electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eCurrent measurement range: 140 A in both directions, i.e., -140 A to +140 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 100 A unlimited - 120 A for 1 minute - 140 A for 20 seconds (However, depending on the connector system, the limits of the connectors are significantly lower!) Sensible values are with - MPX green (double contact) and XT60 continuous: 50 A \/ 20A\u003c\/li\u003e\n\t\u003cli\u003eVoltage measurement range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003eAltitude measurement range: 0 to 8000 m above sea level, automatically zeroed upon power-on\u003c\/li\u003e\n\t\u003cli\u003eReceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003eData rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003ePower supply from receiver power via the telemetry port (from 3.8 V to a maximum of 10 V)\u003c\/li\u003e\n\t\u003cli\u003ePower consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eExternal connections: 1x connection for telemetry and power supply, 1x phase connection for brushless RPM measurement, 1x servo pulse input from receiver, COM connection for UniDisplay, GPS logger, or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eGreen MPX connector: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eYellow XT60 connector: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold connector: 26 (55) x 22 x 9 mm, 5.5 mm gold connector: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold connector: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 10 g - 14 g without cable (depending on connector system), connection cable 4 g\u003c\/li\u003e\n\t\u003cli\u003eScope of delivery: UniSens-E with integrated altimeter \/ variometer, connection cable to receiver for telemetry \/ power supply, connection cable for brushless RPM measurement, detailed colored operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448690073943,"sku":"SM3107","price":46.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3107_b1_27ed51e6-fe34-447f-b182-59c5ada0dbf2.jpg?v=1780300483"},{"product_id":"unisens-e-mit-1-5mm-silikonkabel-max-55a-sm-modellbau-3108","title":"UniSens-E with 1.5mm² silicone cable, max. 55A, SM-Modellbau # 3108","description":"\u003ch1\u003eUniSens-E with 1.5mm silicone cable, max. 55A SM # 3108\u003c\/h1\u003e\n\n\u003cp\u003eWith improved altitude sensor V2. The small, powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless RPM \/ altitude \/ vario.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a pure telemetry sensor specifically for all electric models. It is so small and lightweight, yet so powerful, that it can be used in almost any model. In line with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest and JR DMSS. The UniSens-E automatically recognizes HoTT telemetry systems upon delivery. When used with Jeti, Multiplex, Futaba or JR, the telemetry must be specified in the settings beforehand. To change settings via PC or for firmware updates, a suitable USB interface such as order no. 2550 or an existing USB connection cable such as those from Jeti, Multiplex or Graupner is required. Please refer to the manual for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire drive, i.e. voltage, current, capacity and even RPM. A special feature is that a brushless RPM sensor is already permanently installed. To measure the RPM, only a small cable connection to one of the three motor phases needs to be established with the enclosed cable. Since a barometric (air pressure) altitude sensor with high resolution is also integrated, an altimeter and a vario are realized with the UniSens-E. Extensive alarms can also be programmed, which are reported via telemetry via the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various connector systems, so that no soldering is usually required. The current measurement range extends symmetrically in both directions. This means that the connector assignment, i.e. whether the battery has a male or female plug on the positive pole, does not matter. The measuring direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live directly via our UniDisplay, and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether gliders, aerobatic aircraft, helicopters, HLG or slow flyers, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for model aircraft. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful, universal RC telemetry sensor in all respects, which utilizes the possibilities of modern electronics to be a great help to you as a small helper in dealing with your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecomplete measurement of electric drives with current, voltage, power, capacity, RPM and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eintegrated brushless RPM sensor\u003c\/li\u003e\n\t\u003cli\u003efull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, Fr Sky and Spektrum\u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement with automatic zeroing after power-on, barometric vario\u003c\/li\u003e\n\t\u003cli\u003ecurrent measurement range up to 140 A in both directions, voltage up to 60 V (however, the maximum current carrying capacity of the connectors used must not be exceeded!)\u003c\/li\u003e\n\t\u003cli\u003econnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003edirect connection to GPS logger possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003emeasurement of receiver battery voltage\u003c\/li\u003e\n\t\u003cli\u003epower supply via receiver\u003c\/li\u003e\n\t\u003cli\u003ecurrent status indicated by LED\u003c\/li\u003e\n\t\u003cli\u003edirect viewing of live or recorded measurements with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eparameter settings possible via PC, UniDisplay and telemetry\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool)\u003c\/li\u003e\n\t\u003cli\u003efree firmware updates via PC with our USB interface (order no. 2550) or with existing USB connection cables such as those from Jeti, Multiplex or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003ecan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003ePlease refer to the operating instructions for technical data and the complete range of functions.\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. altitude measurement only with altitude sensor already integrated in the UniSens-E, e.g., in F3B \/ F3J gliders\u003c\/p\u003e\n\n\u003cp\u003e2. electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecurrent measurement range: 140 A in both directions, i.e. - 140 A to + 140 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 100 A unlimited - 120 A for 1 minute - 140 A for 20 seconds (However, depending on the plug system, the limits of the plugs are significantly lower!) Useful values are with - MPX green (double contact) and XT60 continuous: 50 A \/ 20A\u003c\/li\u003e\n\t\u003cli\u003evoltage measurement range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement range: 0 to 8000 m above sea level, automatically zeroed when switched on\u003c\/li\u003e\n\t\u003cli\u003ereceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003edata rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver supply via telemetry connection (from 3.8 V to max. 10 V)\u003c\/li\u003e\n\t\u003cli\u003ecurrent consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eexternal connections: 1 connection for telemetry and power supply 1 phase connection for brushless RPM measurement 1 servo pulse input from receiver COM connection for UniDisplay, GPS logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003egreen MPX connector: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eyellow XT60 connector: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold connector: 26 (55) x 22 x 9 mm 5.5 mm gold connector: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold connector: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eweight: 10 g - 14 g without cable (depending on plug system), connection cable 4 g\u003c\/li\u003e\n\t\u003cli\u003escope of delivery: UniSens-E with integrated altitude sensor \/ vario connection cable to receiver for telemetry \/ power supply connection cable for brushless RPM measurement detailed colored operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448692498775,"sku":"SM3108","price":46.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3108_b1_9d137f59-48e5-40fb-a77f-80d6b5e78aac.jpg?v=1780656244"},{"product_id":"unisens-e-mit-xt-90-seriell-sm-modellbau-3109","title":"UniSens-E with XT-90 Series, SM-Modellbau # 3109","description":"\u003ch1\u003eUniSens-E with XT-90 (serial) power connection, SM # 3109 \u003c\/h1\u003e\n\n\u003cp\u003eWith improved altitude sensor V2 The small powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless speed \/ altitude \/ Vario\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a pure telemetry sensor specially designed for all electric models. It is so small and light, yet so powerful, that it can be used in almost any model. In accordance with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest and JR DMSS. The UniSens-E automatically detects HoTT telemetry systems in its default state. When used with Jeti, Multiplex, Futaba or JR, the telemetry must be specified in the settings beforehand. To change settings via PC or for firmware updates, a suitable USB interface such as item no. 2550 or an existing USB connection cable such as those from Jeti, Multiplex or Graupner is required. Please refer to the instructions for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire drive, i.e. voltage, current, capacity and even speed. A brushless speed sensor is already built in as a special feature. To measure the speed, only a small cable connection to one of the three motor phases needs to be made with the enclosed cable. Since a barometric (air pressure) altitude sensor with high resolution is also integrated, an altimeter and a vario are realized with the UniSens-E. Extensive alarms can also be programmed, which are reported via telemetry through the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various connector systems, so that nothing usually has to be soldered. The current measuring range extends symmetrically in both directions. This means that the pin assignment, i.e. whether the battery has male or female on the positive pole, does not matter. The measuring direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live directly via our UniDisplay and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether gliders, aerobatic aircraft, helicopters, HLG or slow flyers, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for model aircraft. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful universal RC telemetry sensor in all respects, which utilizes the possibilities of modern electronics to be a great help to you as a small helper in dealing with your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecomplete measurement of electric drives with current, voltage, power, capacity, speed and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eintegrated brushless speed sensor\u003c\/li\u003e\n\t\u003cli\u003efull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, Fr Sky and Spektrum \u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement with automatic zeroing after power on, barometric vario\u003c\/li\u003e\n\t\u003cli\u003ecurrent measuring range up to 140 A in both directions, voltage up to 60 V (however, the maximum current carrying capacity of the connectors used must not be exceeded!)\u003c\/li\u003e\n\t\u003cli\u003econnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003edirect connection to GPS logger possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003ereceiver battery voltage measurement\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver\u003c\/li\u003e\n\t\u003cli\u003ecurrent status is signaled via LED\u003c\/li\u003e\n\t\u003cli\u003edirect viewing of measured values live or recorded with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eparameter settings via PC, UniDisplay and telemetry possible\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool) \u003c\/li\u003e\n\t\u003cli\u003efree firmware updates via PC with our USB interface (item no. 2550) or with existing USB connection cables such as those from Jeti, Multiplex or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003ecan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003ePlease refer to the operating instructions for technical data and the complete range of functions. \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. altitude measurement only with altitude sensor already integrated in UniSens-E Application e.g. in F3B \/ F3J glider\u003c\/p\u003e\n\n\u003cp\u003e2. electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eCurrent measuring range: 140 A in both directions, i.e. - 140 A to + 140 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 100 A unlimited - 120 A for 1 minute - 140 A for 20 seconds (However, depending on the plug system, the limits of the plugs are significantly lower!) Meaningful values are with - MPX green (double contact) and XT60 Duration: 50 A \/ 20A \u003c\/li\u003e\n\t\u003cli\u003eVoltage measuring range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003eAltitude measuring range: 0 to 8000 m ASL, automatic zeroing when switched on\u003c\/li\u003e\n\t\u003cli\u003eReceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003eData rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003ePower supply from receiver power supply via the telemetry connection (from 3.8 V to a maximum of 10 V)\u003c\/li\u003e\n\t\u003cli\u003eCurrent consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eexternal connections: 1 connection for telemetry and power supply 1 phase connection for brushless speed measurement 1 servo pulse input from receiver COM connection for UniDisplay, GPS logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003egreen MPX connector: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eyellow XT60 connector: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold connector: 26 (55) x 22 x 9 mm 5.5 mm gold connector: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold connector: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 10 g - 14 g without cable (depending on plug system), connecting cable 4 g\u003c\/li\u003e\n\t\u003cli\u003eScope of delivery: UniSens-E with integrated altitude sensor \/ vario connection cable to receiver for telemetry \/ power supply connection cable for brushless speed measurement detailed color operating instructions \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448695710039,"sku":"SM3109","price":63.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3109_b1.jpg?v=1780292290"},{"product_id":"unisens-e-280-a-mit-6-mm-lmt-goldstecker-sm-modellbau-3114","title":"UniSens-E 280 A with 6 mm LMT Gold Connector, SM-Modellbau # 3114","description":"\u003ch1\u003eUniSens-E 280 A with 6 mm LMT Gold Connector SM # 3114\u003c\/h1\u003e\n\n\u003cp\u003e With improved altimeter sensor V2 The small, powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless RPM \/ altitude \/ vario\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a dedicated telemetry sensor specifically for all electric models. It is so small and light, yet so powerful, that it can be used in almost any model. In accordance with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest, and JR DMSS. The UniSens-E automatically recognizes HoTT telemetry systems out of the box. When used with Jeti, Multiplex, Futaba, or JR, the telemetry must be specified in the settings beforehand. To change settings via PC or for firmware updates, a suitable USB interface, such as part no. 2550, or an existing USB connection cable from Jeti, Multiplex, or Graupner is required. See the manual for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire drive system, including voltage, current, capacity, and even RPM. A special feature is the integrated brushless RPM sensor. To measure RPM, only a small cable connection to one of the three motor phases needs to be made with the included cable. Since a barometric (air pressure) altimeter sensor with high resolution is also integrated, the UniSens-E also provides altitude measurement and a vario. Extensive alarms can also be programmed, which are reported via telemetry through the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various connector systems, so that no soldering is usually necessary. The current measurement range extends symmetrically in both directions. This means that the connector assignment, i.e., whether the battery has male or female at the positive pole, does not matter. The measurement direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live directly via our UniDisplay, and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether gliders, aerobatic aircraft, helicopters, HLG, or slow flyers, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for model aircraft. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful, universal RC telemetry sensor in every respect, which utilizes the possibilities of modern electronics to be a great help to you in handling your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecomplete measurement of electric drives with current, voltage, power, capacity, RPM, and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eintegrated brushless RPM sensor\u003c\/li\u003e\n\t\u003cli\u003efull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, Fr Sky and Spektrum\u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement with automatic zeroing after power-on barometric vario\u003c\/li\u003e\n\t\u003cli\u003ecurrent measurement range up to 280 A in both directions, voltage up to 60 V\u003c\/li\u003e\n\t\u003cli\u003econnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003edirect connection to GPS-Logger 2 possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003emeasurement of receiver battery voltage\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver\u003c\/li\u003e\n\t\u003cli\u003ecurrent status is signaled by LED\u003c\/li\u003e\n\t\u003cli\u003edirect viewing of live or recorded measured values with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eparameter settings via PC, UniDisplay and telemetry possible\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool)\u003c\/li\u003e\n\t\u003cli\u003efree firmware updates via PC with our USB interface (part no. 2550) or with existing USB connection cables from Jeti, Multiplex or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003ecan be used almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eFor technical data and the complete range of functions, please refer to the operating instructions.\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e1. altitude measurement only with altimeter sensor already integrated in the UniSens-E application\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e2. electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecurrent measurement range: 280 A in both directions, i.e., - 280 A to + 280 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 200 A unlimited - 240 A for 1 minute - 280 A for 20 seconds. (However, depending on the plug system, the limits are significantly lower!) Useful values with 6 mm LMT gold connector: Continuous: 140 A \/ 20s: 160 A, 2 x 4mm² silicone cable: Continuous: 160 A \/ 20s: 200A\u003c\/li\u003e\n\t\u003cli\u003evoltage measurement range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement range: 0 to 8000 m above sea level, automatically zeroed when switched on\u003c\/li\u003e\n\t\u003cli\u003ereceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003edata rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver power supply via the telemetry connection (from 3.8 V to a maximum of 10 V)\u003c\/li\u003e\n\t\u003cli\u003epower consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eexternal connections: 1 x connection for telemetry and power supply 1 x phase connection for brushless RPM measurement 1 x servo pulse input from receiver COM connection for UniDisplay, GPS-Logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003egreen MPX connector: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eyellow XT60 connector: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold connector: 26 (55) x 22 x 9 mm 5.5 mm gold connector: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold connector: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eweight: 17g - 30g\u003c\/li\u003e\n\t\u003cli\u003eweight: 10 g - 14 g without cable (depending on plug system), connection cable 4 g\u003c\/li\u003e\n\t\u003cli\u003escope of delivery: UniSens-E with integrated altimeter \/ vario connection cable to receiver for telemetry \/ power supply connection cable for brushless RPM measurement detailed colored operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448698397015,"sku":"SM3114","price":73.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3114_b1_e95865bc-a7ac-4099-8cf8-b98f66ef729f.jpg?v=1779817881"},{"product_id":"unisens-e-280-a-mit-2-x-4-mm-silikonkabel-sm-modellbau-3115","title":"UniSens-E 280 A with 2 x 4 mm² silicone cable, SM-Modellbau # 3115","description":"\u003ch1\u003eUniSens-E 280 A with 2x4.0mm Silicone Cable SM # 3115\u003c\/h1\u003e\n\n\u003cp\u003e With improved V2 altitude sensor. The small yet powerful RC telemetry sensor measures and transmits voltage \/ current \/ power \/ capacity \/ energy \/ brushless RPM \/ altitude \/ variometer.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is a dedicated telemetry sensor specifically for all electric models. It is so small and lightweight, yet so powerful, that it can be used in almost any model. In line with SM-Modellbau's philosophy of supporting as many systems as possible, the UniSens-E also speaks the language of Jeti Duplex (EX), Multiplex M-Link, Graupner HoTT, Robbe\/Futaba FASSTest, and JR DMSS. The UniSens-E automatically recognizes HoTT telemetry systems upon delivery. When used with Jeti, Multiplex, Futaba, or JR, the telemetry must be specified in the settings beforehand. To change settings via PC or for firmware updates, a suitable USB interface like item no. 2550 or an existing USB connection cable from Jeti, Multiplex, or Graupner is required. Please refer to the manual for more information.\u003c\/p\u003e\n\n\u003cp\u003eWithout additional sensors, the UniSens-E can measure the entire propulsion system, including voltage, current, capacity, and even RPM. A special highlight is the integrated brushless RPM sensor. To measure RPM, only a small cable connection to one of the three motor phases needs to be made using the included cable. Since a barometric (air pressure) altitude sensor with high resolution is also integrated, an altimeter and variometer are realized with the UniSens-E. Extensive alarms can also be programmed, which are reported via telemetry through the respective transmitter.\u003c\/p\u003e\n\n\u003cp\u003eThe UniSens-E is available with various connector systems, so soldering is usually not necessary. The current measurement range extends symmetrically in both directions. This means that the connector assignment, i.e., whether the battery has male or female on the positive pole, does not matter. The measurement direction is simply set in the setup. All measured values of the UniSens-E can also be viewed live directly via our UniDisplay, and all settings and alarms can be programmed.\u003c\/p\u003e\n\n\u003cp\u003eWhether gliders, aerobatic aircraft, helicopters, HLGs, or slow flyers, the UniSens-E can be used in almost any area due to its low weight and compact size. Of course, the UniSens-E is not only suitable for model aircraft. It can also be installed in RC boats, RC cars, etc.\u003c\/p\u003e\n\n\u003cp\u003eWith the UniSens-E, you acquire a powerful universal RC telemetry sensor in all respects, which utilizes the possibilities of modern electronics to be a great help to you as a small assistant in dealing with your RC models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eAnd this is what the UniSens-E can do:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecomplete measurement of electric drives with current, voltage, power, capacity, RPM, and altitude measurement\u003c\/li\u003e\n\t\u003cli\u003eintegrated brushless RPM sensor\u003c\/li\u003e\n\t\u003cli\u003efull telemetry support for Jeti Duplex (EX), PowerBox Core, Multiplex M-Link, Graupner HoTT, Futaba FASSTest S.BUS2, JR DMSS, Fr Sky and Spektrum \u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement with automatic zeroing after power-on barometric variometer\u003c\/li\u003e\n\t\u003cli\u003ecurrent measurement range up to 280 A in both directions, voltage up to 60 V \u003c\/li\u003e\n\t\u003cli\u003econnection for receiver signal for remote control of certain functions\u003c\/li\u003e\n\t\u003cli\u003edirect connection to GPS logger 2 possible for data recording in a file\u003c\/li\u003e\n\t\u003cli\u003emeasurement of receiver battery voltage\u003c\/li\u003e\n\t\u003cli\u003epower supply via receiver\u003c\/li\u003e\n\t\u003cli\u003ecurrent status indicated by LED\u003c\/li\u003e\n\t\u003cli\u003edirect viewing of live or recorded measurements with our UniDisplay\u003c\/li\u003e\n\t\u003cli\u003eparameter settings possible via PC, UniDisplay and telemetry\u003c\/li\u003e\n\t\u003cli\u003ePC software for settings and updates (SM UniSens-E Tool) \u003c\/li\u003e\n\t\u003cli\u003efree firmware updates via PC with our USB interface (item no. 2550) or with existing USB connection cables from Jeti, Multiplex or Graupner (the firmware file can be found here)\u003c\/li\u003e\n\t\u003cli\u003eusable almost anywhere due to its compact size and low weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eFor technical data and the complete range of functions, please refer to the operating manual.   \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTypical wiring examples of the UniSens-E in the model: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e1. altitude measurement only with the altitude sensor already integrated in the UniSens-E application\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e2. electric drive measurement\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eTechnical data: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ecurrent measurement range: 280 A in both directions, i.e., - 280 A to + 280 A\u003c\/li\u003e\n\t\u003cli\u003eThe following load durations are permissible: - 200 A unlimited - 240 A for 1 minute - 280 A for 20 seconds. Depending on the connector system, however, the limits are significantly lower!)  Sensible values are with 6 mm LMT gold connector: Continuous: 140 A \/ 20s: 160 A, 2 x 4mm² silicone cable: Continuous: 160 A \/ 20s: 200A \u003c\/li\u003e\n\t\u003cli\u003evoltage measurement range: 0 to 60 V\u003c\/li\u003e\n\t\u003cli\u003ealtitude measurement range: 0 to 8000 m ASL, automatically zeroed upon power-on\u003c\/li\u003e\n\t\u003cli\u003ereceiver voltage measurement: 3.8 V to 10 V\u003c\/li\u003e\n\t\u003cli\u003edata rate: 10 Hz\u003c\/li\u003e\n\t\u003cli\u003epower supply from receiver power supply via the telemetry connection (from 3.8 V to a maximum of 10 V)\u003c\/li\u003e\n\t\u003cli\u003ecurrent consumption: approx. 25 mA\u003c\/li\u003e\n\t\u003cli\u003eexternal connections: 1 connection for telemetry and power supply 1 phase connection for brushless RPM measurement 1 servo pulse input from receiver COM connection for UniDisplay, GPS logger or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eDimensions: \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003egreen MPX connector: 26 (38) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003eyellow XT60 connector: 26 (50) x 29 x 9 mm\u003c\/li\u003e\n\t\u003cli\u003e4 mm gold connector: 26 (55) x 22 x 9 mm 5.5 mm gold connector: 26 (44) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003e6 mm LMT gold connector: 26 (42) x 22 x 11 mm\u003c\/li\u003e\n\t\u003cli\u003eweight: 17g - 30g\u003c\/li\u003e\n\t\u003cli\u003eweight: 10 g - 14 g without cable (depending on connector system), connection cable 4 g\u003c\/li\u003e\n\t\u003cli\u003escope of delivery: UniSens-E with integrated altitude sensor \/ variometer connection cable to the receiver for telemetry \/ power supply connection cable for brushless RPM measurement detailed color operating manual \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53448701313367,"sku":"SM3115","price":73.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/SM3115_b1.jpg?v=1779935509"},{"product_id":"unilog-stromsensor-200a-mit-6mm-lmt-gold-f5b-akku-stecker-sm-2519","title":"UNILog Current Sensor 200A with 6mm LMT Gold F5B (Battery - = Plug), SM # 2519","description":"\u003ch1\u003eUNILog Current Sensor 200 A with 6mm LMT Gold Connector F5B\u003cbr\u003e\n(for batteries with female connector on the positive terminal)\u003c\/h1\u003e","brand":"SM-Modellbau","offers":[{"title":"Default Title","offer_id":53449111077207,"sku":"SM2519","price":23.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/files\/unilog-stromsensor-200-a-6-mm-lmt-gold-f5b-akkus-mit-buchse-am-pluspol.jpg?v=1779819553"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/8318\/0119\/collections\/Strom-Sensor-35A-fuer-M-LINK-Empfaenger-m-MPX-Steckverbindung-Multiplex-85403-M85403_b_0.jpg?v=1771408940","url":"https:\/\/hoelleinshop.com\/en\/collections\/fernsteuerungen-zubehor-telemetrie-strom-spannung.oembed?page=2","provider":"hoelleinshop","version":"1.0","type":"link"}